TOTAL POLYPHENOLS CONTENT DETERMINATION IN COMPLEX MATRIX OF MEDICINAL PLANTS FROM ROMANIA BY NIR SPECTROSCOPY
Monica Hărmănescu, Alexandru Moisuc, Florina Radu, Simona Ruxanda Dragan, I. Gergen
Abstract
Monica Hărmănescu, Alexandru Moisuc, Florina Radu, Simona Ruxanda Dragan, I. Gergen
Abstract
The main objective of this study is to present our researches regarding the determination of total polyphenols content of seventeen medicinal plants from Romania using NIR Spectroscopy. For this it were performed correlations between the values obtained for total polyphenols content (mM/g) using a chemical method with Folin Ciocalteau reagent and the reflectance values of frequencies from NIR spectra. To obtain the main parameters of the regression model for total polyphenols content determination using NIR Spectroscopy it was used PLS-Laverage method of UNSCRAMBLE software. The correlation coefficient R2 obtained for regression equation was equal with 0.994752. The good quality of prediction of obtained PLS-Leverage model was done by the small values of the deviation, between 6% and 8%.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The main objective of this study is to present our researches regarding the determination of total polyphenols content of seventeen medicinal plants from Romania using NIR Spectroscopy. For this it were performed correlations between the values obtained for total polyphenols content (mM/g) using a chemical method with Folin Ciocalteau reagent and the reflectance values of frequencies from NIR spectra. To obtain the main parameters of the regression model for total polyphenols content determination using NIR Spectroscopy it was used PLS-Laverage method of UNSCRAMBLE software. The correlation coefficient R2 obtained for regression equation was equal with 0.994752. The good quality of prediction of obtained PLS-Leverage model was done by the small values of the deviation, between 6% and 8%.
Key concepts: Polyphenol, Chemistry, Coefficient of determination, Correlation coefficient, Leverage (statistics), Content (measure theory), Spectroscopy, Content determination