2004AIP conference proceedingsRequires access

The Re-design of a Soft X-ray Beamline for Photoemission Spectroscopy at NSRL

Xiaojiang Yu

Open publisher page 1 citations

Abstract

The monochromator of the old soft x‐ray beamline for photoemission spectroscopy covering spectral range from 60 –1000 eV was designed according to Rowland Circle Monochromator for energy resolution (E/ΔE) over 2000 with slit widths of 40 μm at NSRL. But the beamline suffers of low flux with high energy over 500 eV cut off and energy resolution bellow 1000 at practical flux. We reconstruct the beamline by replacement of the Kirkpatrick‐Baez pre‐focusing optics and the monochromator, energy resolution beyond 1000 and flux over 5×109 photons/s can be obtained with 50 μm slit widths.

About this research paper

What this paper is about

The monochromator of the old soft x‐ray beamline for photoemission spectroscopy covering spectral range from 60 –1000 eV was designed according to Rowland Circle Monochromator for energy resolution (E/ΔE) over 2000 with slit widths of 40 μm at NSRL. But the beamline suffers of low flux with high energy over 500 eV cut off and energy resolution bellow 1000 at practical flux. We reconstruct the beamline by replacement of the Kirkpatrick‐Baez pre‐focusing optics and the monochromator, energy resolution beyond 1000 and flux over 5×109 photons/s can be obtained with 50 μm slit widths.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The monochromator of the old soft x‐ray beamline for photoemission spectroscopy covering spectral range from 60 –1000 eV was designed according to Rowland Circle Monochromator for energy resolution (E/ΔE) over 2000 with slit widths of 40 μm at NSRL. But the beamline suffers of low flux with high energy over 500 eV cut off and energy resolution bellow 1000 at practical flux. We reconstruct the beamline by replacement of the Kirkpatrick‐Baez pre‐focusing optics and the monochromator, energy resolution beyond 1000 and flux over 5×109 photons/s can be obtained with 50 μm slit widths.