2007AIP conference proceedingsRequires access

Performance of a Highly Stabilized and High-resolution Beamline BL17SU for Advanced Soft X-ray Spectroscopy at SPring-8

Haruhiko Ohashi, Yasunori Senba, Hikaru Kishimoto, Takanori Miura, Eiji Ishiguro, Tomoyuki Takeuchi, Masaki Oura, K. Shirasawa, T. Tanaka, Masao Takeuchi, Kunikazu Takeshita, Shunji Goto, Sunao Takahashi, H. Aoyagi, Mutsumi Sano, Yukito Furukawa, Toru Ohata, T. Matsushita, Yasuhide Ishizawa, Shingo Taniguchi, Yoshihiro Asano, Yoshihisa Harada, Takashi Tokushima, Koji Horiba, Hideo Kitamura, Tetsuya Ishikawa, Shik Shin

Open publisher page 86 citations

Abstract

A new soft x‐ray beamline BL17SU (RIKEN) has been constructed at SPring‐8. The beamline consists of two branches with each varied‐line‐spacing‐plane‐grating‐monochromator. Both monochromators perform high energy resolution (E/ΔE > 10,000) between 0.2 and 1 keV. One of the monochromator achieves high energy stability of 10 meV over a period of half a day.

About this research paper

What this paper is about

A new soft x‐ray beamline BL17SU (RIKEN) has been constructed at SPring‐8. The beamline consists of two branches with each varied‐line‐spacing‐plane‐grating‐monochromator. Both monochromators perform high energy resolution (E/ΔE > 10,000) between 0.2 and 1 keV. One of the monochromator achieves high energy stability of 10 meV over a period of half a day.

Why it matters

OpenAlex reports 86 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new soft x‐ray beamline BL17SU (RIKEN) has been constructed at SPring‐8. The beamline consists of two branches with each varied‐line‐spacing‐plane‐grating‐monochromator. Both monochromators perform high energy resolution (E/ΔE > 10,000) between 0.2 and 1 keV. One of the monochromator achieves high energy stability of 10 meV over a period of half a day.

Key concepts: Monochromator, Beamline, SPring-8, Optics, Grating, Soft X-rays, Spectroscopy, Line (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of a Highly Stabilized and High-resolution Beamline BL17SU for Advanced Soft X-ray Spectroscopy at SPring-8 — Research Paper | ScholarLens