Effects of implant neck design on primary stability and overload in a type IV mandibular bone
I‐Chiang Chou, Shyh‐Yuan Lee, Cho‐Pei Jiang
Abstract
I‐Chiang Chou, Shyh‐Yuan Lee, Cho‐Pei Jiang
Abstract
This study investigates the effect of implant neck design on primary stability and overload using 3D finite element analysis. Four commercial dental implants and mandibular segments are created. Various parameters including the osseointegration condition (non-osseointegration and full osseointegration), force direction (vertical and horizontal), and cortical bone thickness (Tc = 0.3, 0.5, and 1 mm) are considered. The vertical and horizontal forces, 500 N and 250 N, are statically applied at the top of the platform, respectively. Micromotion and von Mises stress are employed to evaluate the risk of osseointegration and bone fatigue before osseointegration condition. After osseointegration, the principal stress is used to analyze the bone overload. Maximal von Mises stress and micromotion of the peri-implant bone decreased as cortical bone thickness increased. Horizontal force induces stress concentration in the bone around the implant neck easier than that of vertical force, and it may result in crestal bone loss. Thinner cortical bone should avoid dental implantation because it causes a noteworthy larger micromotion and stress concentration in cortical bone in particular Tc less than 0.3 mm.
OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study investigates the effect of implant neck design on primary stability and overload using 3D finite element analysis. Four commercial dental implants and mandibular segments are created. Various parameters including the osseointegration condition (non-osseointegration and full osseointegration), force direction (vertical and horizontal), and cortical bone thickness (Tc = 0.3, 0.5, and 1 mm) are considered. The vertical and horizontal forces, 500 N and 250 N, are statically applied at the top of the platform, respectively. Micromotion and von Mises stress are employed to evaluate the risk of osseointegration and bone fatigue before osseointegration condition. After osseointegration, the principal stress is used to analyze the bone overload. Maximal von Mises stress and micromotion of the peri-implant bone decreased as cortical bone thickness increased. Horizontal force induces stress concentration in the bone around the implant neck easier than that of vertical force, and it may result in crestal bone loss. Thinner cortical bone should avoid dental implantation because it causes a noteworthy larger micromotion and stress concentration in cortical bone in particular Tc less than 0.3 mm.
Key concepts: Osseointegration, von Mises yield criterion, Cortical bone, Implant, Dental implant, Dentistry, Materials science, Stress (linguistics)