2007Journal of the Korean Academy of Clinical ElectrophysiologyRequires access

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold

Seok-Ju Choi, Sang-Wan Lim, Su-Hyon Kim, Dal-Ju Mun

Open publisher page 1 citations

Abstract

INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P

About this research paper

What this paper is about

INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P

Key concepts: Vastus medialis, Electromyography, Isometric exercise, Rectus femoris muscle, Medicine, Thigh, Sitting, Muscle contraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold — Research Paper | ScholarLens