2001PubMedRequires access

Effects of heat and cold application on turns and amplitude in surface EMG.

Klaus‐Henning Krause, I. Magyarosy, Heinrich Gall, Edzard Ernst, Dieter E. Pongratz, Peter Schoeps

Open publisher page 8 citations

Abstract

The purpose of this study was to investigate the effects of cooling and heating of muscles on parameters of surface EMG (SEMG) under various well defined grades of isometric muscle contraction. In 32 healthy volunteers, aged 20-30 years, turns and amplitude (RMS) analysis was done in SEMG from the hand extensors. Muscle strength was defined by a new developed hand dynamometer. Values for RMS and turns in case of maximal voluntary contraction (MVC) over periods of 20 sec were determined for each volunteer and subsequently RMS and turns were measured during isometric contractions of 10%, 30%, 50% and 80% of MVC, interrupted each by rest periods. This procedure was repeated after cooling and warming the forearm with thermo packs. For control purposes the same investigations with three measurement periods of SEMG were done following the same time schedule without thermic stimuli. With increasing isometric contractions turns increased after heat application and decreased after ice application, compared to the values achieved without thermic stimuli. The differences were significant from a level of 30% of MVC (p < 0.05). No corresponding changes were seen for RMS. In the control experiment values of turns and RMS did not differ in the three measurement periods. It is concluded, that the amplitude in SEMG tracings seems to be a reliable parameter of muscle force, whereas turns are sensitive to temperature. They might be useful markers for therapeutic approaches targeted at the muscle.

About this research paper

What this paper is about

The purpose of this study was to investigate the effects of cooling and heating of muscles on parameters of surface EMG (SEMG) under various well defined grades of isometric muscle contraction. In 32 healthy volunteers, aged 20-30 years, turns and amplitude (RMS) analysis was done in SEMG from the hand extensors. Muscle strength was defined by a new developed hand dynamometer. Values for RMS and turns in case of maximal voluntary contraction (MVC) over periods of 20 sec were determined for each volunteer and subsequently RMS and turns were measured during isometric contractions of 10%, 30%, 50% and 80% of MVC, interrupted each by rest periods. This procedure was repeated after cooling and warming the forearm with thermo packs. For control purposes the same investigations with three measurement periods of SEMG were done following the same time schedule without thermic stimuli. With increasing isometric contractions turns increased after heat application and decreased after ice application, compared to the values achieved without thermic stimuli. The differences were significant from a level of 30% of MVC (p < 0.05). No corresponding changes were seen for RMS. In the control experiment values of turns and RMS did not differ in the three measurement periods. It is concluded, that the amplitude in SEMG tracings seems to be a reliable parameter of muscle force, whereas turns are sensitive to temperature. They might be useful markers for therapeutic approaches targeted at the muscle.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to investigate the effects of cooling and heating of muscles on parameters of surface EMG (SEMG) under various well defined grades of isometric muscle contraction. In 32 healthy volunteers, aged 20-30 years, turns and amplitude (RMS) analysis was done in SEMG from the hand extensors. Muscle strength was defined by a new developed hand dynamometer. Values for RMS and turns in case of maximal voluntary contraction (MVC) over periods of 20 sec were determined for each volunteer and subsequently RMS and turns were measured during isometric contractions of 10%, 30%, 50% and 80% of MVC, interrupted each by rest periods. This procedure was repeated after cooling and warming the forearm with thermo packs. For control purposes the same investigations with three measurement periods of SEMG were done following the same time schedule without thermic stimuli. With increasing isometric contractions turns increased after heat application and decreased after ice application, compared to the values achieved without thermic stimuli. The differences were significant from a level of 30% of MVC (p < 0.05). No corresponding changes were seen for RMS. In the control experiment values of turns and RMS did not differ in the three measurement periods. It is concluded, that the amplitude in SEMG tracings seems to be a reliable parameter of muscle force, whereas turns are sensitive to temperature. They might be useful markers for therapeutic approaches targeted at the muscle.

Key concepts: Isometric exercise, Dynamometer, Electromyography, Amplitude, Forearm, Contraction (grammar), Muscle contraction, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of heat and cold application on turns and amplitude in surface EMG. — Research Paper | ScholarLens