2004AIP conference proceedingsRequires access

Crystal Monochromator based Emittance Measurements at the PETRA Undulator Beamline

Ulrich Hahn

Open publisher page 2 citations

Abstract

The synchrotron radiation beamline at the PETRA storage ring at DESY with two end stations uses a 4 m‐long undulator delivering hard X‐ray photons up to 300 keV at a storage ring energy of 12 GeV. The spatial photon intensity distribution at the first undulator harmonic (21.23 keV) was used to determine the horizontal emittance of the storage ring. The set‐up installed at 107.7 m from the source point consists of a vacuum chamber with a cryogenically cooled silicon crystal in Laue geometry. The monochromatized radiation is converted to visible light by a fluorescent screen on the back of an aluminum plate and observed by a digital camera. Gaussian fits to horizontal lines through the centre of mass of the images provide the standard deviations of the measured intensity distributions in the horizontal plane. The corresponding emittance values were derived by modeling the whole setup with the SPECTRA code using the emittance as a free parameter and by using machine physics formulas neglecting photon source size effects.

About this research paper

What this paper is about

The synchrotron radiation beamline at the PETRA storage ring at DESY with two end stations uses a 4 m‐long undulator delivering hard X‐ray photons up to 300 keV at a storage ring energy of 12 GeV. The spatial photon intensity distribution at the first undulator harmonic (21.23 keV) was used to determine the horizontal emittance of the storage ring. The set‐up installed at 107.7 m from the source point consists of a vacuum chamber with a cryogenically cooled silicon crystal in Laue geometry. The monochromatized radiation is converted to visible light by a fluorescent screen on the back of an aluminum plate and observed by a digital camera. Gaussian fits to horizontal lines through the centre of mass of the images provide the standard deviations of the measured intensity distributions in the horizontal plane. The corresponding emittance values were derived by modeling the whole setup with the SPECTRA code using the emittance as a free parameter and by using machine physics formulas neglecting photon source size effects.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The synchrotron radiation beamline at the PETRA storage ring at DESY with two end stations uses a 4 m‐long undulator delivering hard X‐ray photons up to 300 keV at a storage ring energy of 12 GeV. The spatial photon intensity distribution at the first undulator harmonic (21.23 keV) was used to determine the horizontal emittance of the storage ring. The set‐up installed at 107.7 m from the source point consists of a vacuum chamber with a cryogenically cooled silicon crystal in Laue geometry. The monochromatized radiation is converted to visible light by a fluorescent screen on the back of an aluminum plate and observed by a digital camera. Gaussian fits to horizontal lines through the centre of mass of the images provide the standard deviations of the measured intensity distributions in the horizontal plane. The corresponding emittance values were derived by modeling the whole setup with the SPECTRA code using the emittance as a free parameter and by using machine physics formulas neglecting photon source size effects.

Key concepts: Undulator, Monochromator, Storage ring, Beamline, Thermal emittance, Physics, DESY, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Crystal Monochromator based Emittance Measurements at the PETRA Undulator Beamline — Research Paper | ScholarLens