WorldSID Production Dummy Biomechanical Responses
Risa D. Scherer, K Bortensclager, Akihiko Akiyama, Suzanne J. Tylko, M Hartlieb, Takeshi Harigae
Abstract
Risa D. Scherer, K Bortensclager, Akihiko Akiyama, Suzanne J. Tylko, M Hartlieb, Takeshi Harigae
Abstract
The results of biomechanical testing of the WorldSID production dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. Based on previous testing the dummy design was frozen and developed into a production version of the WorldSID dummy. This dummy has been tested to determine that the biofidelity of the dummy has not degraded during its development and refinement. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. This dummy has been subjected to a rigorous program of testing to evaluate its biofidelity. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID was calculated using the weighted biomechanical test response procedure developed by ISO. The WorldSID dummy has an overall ISO Biofidelity rating of 8.0, which corresponds to an ISO classification of good. In addition the dummy shows good repeatability and good reproducibility. A comparison of the WorldSID dummy biofidelity compared to other existing side impact dummies biofidelity ratings will also be provided. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0505.pdf For the covering abstract see ITRD E145407.
OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The results of biomechanical testing of the WorldSID production dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. Based on previous testing the dummy design was frozen and developed into a production version of the WorldSID dummy. This dummy has been tested to determine that the biofidelity of the dummy has not degraded during its development and refinement. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. This dummy has been subjected to a rigorous program of testing to evaluate its biofidelity. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID was calculated using the weighted biomechanical test response procedure developed by ISO. The WorldSID dummy has an overall ISO Biofidelity rating of 8.0, which corresponds to an ISO classification of good. In addition the dummy shows good repeatability and good reproducibility. A comparison of the WorldSID dummy biofidelity compared to other existing side impact dummies biofidelity ratings will also be provided. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0505.pdf For the covering abstract see ITRD E145407.
Key concepts: Hybrid III, Engineering, Simulation, Computer science, Reliability engineering, Crash, Programming language