2009•PROCEEDINGS OF THE 21ST (ESV) INTERNATIONAL TECHNICAL CONFERENCE ON THE ENHANCED SAFETY OF VEHICLES, HELD JUNE 2009, STUTTGART, GERMANYRequires access

WorldSID Production Dummy Biomechanical Responses

Risa D. Scherer, K Bortensclager, Akihiko Akiyama, Suzanne J. Tylko, M Hartlieb, Takeshi Harigae

Open publisher page 18 citations

Abstract

The results of biomechanical testing of the WorldSID production dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. Based on previous testing the dummy design was frozen and developed into a production version of the WorldSID dummy. This dummy has been tested to determine that the biofidelity of the dummy has not degraded during its development and refinement. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. This dummy has been subjected to a rigorous program of testing to evaluate its biofidelity. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID was calculated using the weighted biomechanical test response procedure developed by ISO. The WorldSID dummy has an overall ISO Biofidelity rating of 8.0, which corresponds to an ISO classification of good. In addition the dummy shows good repeatability and good reproducibility. A comparison of the WorldSID dummy biofidelity compared to other existing side impact dummies biofidelity ratings will also be provided. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0505.pdf For the covering abstract see ITRD E145407.

About this research paper

What this paper is about

The results of biomechanical testing of the WorldSID production dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. Based on previous testing the dummy design was frozen and developed into a production version of the WorldSID dummy. This dummy has been tested to determine that the biofidelity of the dummy has not degraded during its development and refinement. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. This dummy has been subjected to a rigorous program of testing to evaluate its biofidelity. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID was calculated using the weighted biomechanical test response procedure developed by ISO. The WorldSID dummy has an overall ISO Biofidelity rating of 8.0, which corresponds to an ISO classification of good. In addition the dummy shows good repeatability and good reproducibility. A comparison of the WorldSID dummy biofidelity compared to other existing side impact dummies biofidelity ratings will also be provided. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0505.pdf For the covering abstract see ITRD E145407.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The results of biomechanical testing of the WorldSID production dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. Based on previous testing the dummy design was frozen and developed into a production version of the WorldSID dummy. This dummy has been tested to determine that the biofidelity of the dummy has not degraded during its development and refinement. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. This dummy has been subjected to a rigorous program of testing to evaluate its biofidelity. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID was calculated using the weighted biomechanical test response procedure developed by ISO. The WorldSID dummy has an overall ISO Biofidelity rating of 8.0, which corresponds to an ISO classification of good. In addition the dummy shows good repeatability and good reproducibility. A comparison of the WorldSID dummy biofidelity compared to other existing side impact dummies biofidelity ratings will also be provided. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0505.pdf For the covering abstract see ITRD E145407.

Key concepts: Hybrid III, Engineering, Simulation, Computer science, Reliability engineering, Crash, Programming language