2001•SAE technical papers on CD-ROM/SAE technical paper seriesRequires access

WorldSID Prototype Dummy Biomechanical Responses

Dominique Cesari, Sabine Compigne, Risa D. Scherer, Lan Xu, Nobuhiko Takahashi, Martin Pagé, Kazuhito Asakawa, Greg Kostyniuk, Edmund Hautmann, Klaus Bortenschlager, Minoru Sakurai, Takeshi Harigae

Open publisher page 17 citations

Abstract

The results of biomechanical testing of the WorldSID prototype dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. The first prototype of this dummy has been evaluated by the WorldSID Task Group against previously established corridors for its critical body regions. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. The prototype is the first version of the WorldSID dummy to be built and tested. This dummy has been subjected to a rigorous program of testing to evaluate, first and foremost its biofidelity, but also its repeatability. Following this initial evaluation, any required modifications will be incorporated into a pre-production version of the WorldSID dummy so that it rates "good" to "excellent" on the ISO dummy biofidelity scale - a rating exceeding that of all current side impact dummies. Also, the overall WorldSID repeatability must not exceed a coefficient of variation of 7% at injury assessment level and this has to be verified for the different body regions. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID prototype was calculated using the weighted biomechanical test response procedure developed by ISO. The paper presents the results of the testing, which give a very positive indication of the dummy's potential. Based on this evaluation of the dummy biofidelity, the WorldSID prototype dummy exhibits a biofidelity rating of 6.15 that corresponds to an ISO biofidelity classification of "fair". In addition, the dummy shows good repeatability with a global coefficient of variation of 3.30% for the pendulum and rigid sled tests.

About this research paper

What this paper is about

The results of biomechanical testing of the WorldSID prototype dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. The first prototype of this dummy has been evaluated by the WorldSID Task Group against previously established corridors for its critical body regions. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. The prototype is the first version of the WorldSID dummy to be built and tested. This dummy has been subjected to a rigorous program of testing to evaluate, first and foremost its biofidelity, but also its repeatability. Following this initial evaluation, any required modifications will be incorporated into a pre-production version of the WorldSID dummy so that it rates "good" to "excellent" on the ISO dummy biofidelity scale - a rating exceeding that of all current side impact dummies. Also, the overall WorldSID repeatability must not exceed a coefficient of variation of 7% at injury assessment level and this has to be verified for the different body regions. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID prototype was calculated using the weighted biomechanical test response procedure developed by ISO. The paper presents the results of the testing, which give a very positive indication of the dummy's potential. Based on this evaluation of the dummy biofidelity, the WorldSID prototype dummy exhibits a biofidelity rating of 6.15 that corresponds to an ISO biofidelity classification of "fair". In addition, the dummy shows good repeatability with a global coefficient of variation of 3.30% for the pendulum and rigid sled tests.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The results of biomechanical testing of the WorldSID prototype dummy are presented in this paper. The WorldSID dummy is a new, advanced Worldwide Side Impact Dummy that has the anthropometry of a mid-sized adult male. The first prototype of this dummy has been evaluated by the WorldSID Task Group against previously established corridors for its critical body regions. The response corridors are defined in the International Organization of Standardization (ISO) Technical Report 9790. The prototype is the first version of the WorldSID dummy to be built and tested. This dummy has been subjected to a rigorous program of testing to evaluate, first and foremost its biofidelity, but also its repeatability. Following this initial evaluation, any required modifications will be incorporated into a pre-production version of the WorldSID dummy so that it rates "good" to "excellent" on the ISO dummy biofidelity scale - a rating exceeding that of all current side impact dummies. Also, the overall WorldSID repeatability must not exceed a coefficient of variation of 7% at injury assessment level and this has to be verified for the different body regions. The dummy's head, neck, thorax, abdomen and pelvis were evaluated against the ISO technical report requirements. Testing included drop tests, pendulum impacts, and sled tests. The biofidelity rating of the WorldSID prototype was calculated using the weighted biomechanical test response procedure developed by ISO. The paper presents the results of the testing, which give a very positive indication of the dummy's potential. Based on this evaluation of the dummy biofidelity, the WorldSID prototype dummy exhibits a biofidelity rating of 6.15 that corresponds to an ISO biofidelity classification of "fair". In addition, the dummy shows good repeatability with a global coefficient of variation of 3.30% for the pendulum and rigid sled tests.

Key concepts: Hybrid III, Repeatability, Computer science, Simulation, Reliability engineering, Engineering, Crash, Statistics