2013•Biomedical ChromatographyRequires access

Combined solid‐phase microextraction and high‐performance liquid chromatography with ultroviolet detection for simultaneous analysis of clenbuterol, salbutamol and ractopamine in pig samples

Wei Du, Siruo Zhang, Qiang Fu, Gang Zhao, Chun Ming Chang

Open publisher page 39 citations

Abstract

A simple and sensitive method based on the combination of solid-phase microextraction (SPME) and high-performance liquid chromatography with ultroviolet detection was developed for the simultaneous determination of clenbuterol, salbutamol and ractopamine in pig samples. Parameters of the SPME procedure affecting extraction efficiency, such as the type of fiber, extraction time, extraction temperature, ion strength, pH of sample and stirring rate, were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.5-50 µg/L for clenbuterol and ractopamine, and 0.2-20 µg/L for salbutamol. The limits of detection were 0.1 µg/L for clenbuterol, 0.05 µg/L for salbutamol and 0.1 μg/L for ractopamine, respectively. The averages of intra- and inter-day accuracy ranged from 79.8 to 92.4%. The intra-day and inter-day precision were below 9.6% for the three analytes. This method exhibited the advantages of simplicity, rapidity and low solvent consumption, and was suitable for the monitoring of β2 -agonists residue in pig samples.

About this research paper

What this paper is about

A simple and sensitive method based on the combination of solid-phase microextraction (SPME) and high-performance liquid chromatography with ultroviolet detection was developed for the simultaneous determination of clenbuterol, salbutamol and ractopamine in pig samples. Parameters of the SPME procedure affecting extraction efficiency, such as the type of fiber, extraction time, extraction temperature, ion strength, pH of sample and stirring rate, were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.5-50 µg/L for clenbuterol and ractopamine, and 0.2-20 µg/L for salbutamol. The limits of detection were 0.1 µg/L for clenbuterol, 0.05 µg/L for salbutamol and 0.1 μg/L for ractopamine, respectively. The averages of intra- and inter-day accuracy ranged from 79.8 to 92.4%. The intra-day and inter-day precision were below 9.6% for the three analytes. This method exhibited the advantages of simplicity, rapidity and low solvent consumption, and was suitable for the monitoring of β2 -agonists residue in pig samples.

Why it matters

OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and sensitive method based on the combination of solid-phase microextraction (SPME) and high-performance liquid chromatography with ultroviolet detection was developed for the simultaneous determination of clenbuterol, salbutamol and ractopamine in pig samples. Parameters of the SPME procedure affecting extraction efficiency, such as the type of fiber, extraction time, extraction temperature, ion strength, pH of sample and stirring rate, were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.5-50 µg/L for clenbuterol and ractopamine, and 0.2-20 µg/L for salbutamol. The limits of detection were 0.1 µg/L for clenbuterol, 0.05 µg/L for salbutamol and 0.1 μg/L for ractopamine, respectively. The averages of intra- and inter-day accuracy ranged from 79.8 to 92.4%. The intra-day and inter-day precision were below 9.6% for the three analytes. This method exhibited the advantages of simplicity, rapidity and low solvent consumption, and was suitable for the monitoring of β2 -agonists residue in pig samples.

Key concepts: Ractopamine, Clenbuterol, Chromatography, Chemistry, Salbutamol, Detection limit, Extraction (chemistry), Analyte

Related papers

Back to paper searchBrowse research topicsOriginal source
Combined solid‐phase microextraction and high‐performance liquid chromatography with ultroviolet detection for simultaneous analysis of clenbuterol, salbutamol and ractopamine in pig samples — Research Paper | ScholarLens