2015Unpublished venueRequires access

Determination of radiated emissions of an electrically large EUT: Simulation and experiment

Xiaowei Wang, Ralf Vick

Open publisher page 3 citations

Abstract

The radiated emission testing of an electrically large equipment under test (EUT) has been carried out in a mode stirred chamber and a fully anechoic room. The radiation pattern of a rectangular metallic enclosure with a rectangular slot was measured, simulated and compared. The model of the EUT was then used for a statistical analysis of the expected value of the maximum directivity from 1GHz to 6GHz by numerical simulation. The statistical properties of the simulated directivity matches well with theoretical derivations. The results reveal that the expected value of the maximum directivity could be assumed as a function of electrical size of the EUT. The long term aim of the investigation is the estimation of the directivity of EUTs to correlate measurements of radiated emissions of electrically large EUTs in different test environments. By knowledge of directivity values and the measured total radiated power in an alternative test site, the maximum electric field strength of the EUT could be determined.

About this research paper

What this paper is about

The radiated emission testing of an electrically large equipment under test (EUT) has been carried out in a mode stirred chamber and a fully anechoic room. The radiation pattern of a rectangular metallic enclosure with a rectangular slot was measured, simulated and compared. The model of the EUT was then used for a statistical analysis of the expected value of the maximum directivity from 1GHz to 6GHz by numerical simulation. The statistical properties of the simulated directivity matches well with theoretical derivations. The results reveal that the expected value of the maximum directivity could be assumed as a function of electrical size of the EUT. The long term aim of the investigation is the estimation of the directivity of EUTs to correlate measurements of radiated emissions of electrically large EUTs in different test environments. By knowledge of directivity values and the measured total radiated power in an alternative test site, the maximum electric field strength of the EUT could be determined.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The radiated emission testing of an electrically large equipment under test (EUT) has been carried out in a mode stirred chamber and a fully anechoic room. The radiation pattern of a rectangular metallic enclosure with a rectangular slot was measured, simulated and compared. The model of the EUT was then used for a statistical analysis of the expected value of the maximum directivity from 1GHz to 6GHz by numerical simulation. The statistical properties of the simulated directivity matches well with theoretical derivations. The results reveal that the expected value of the maximum directivity could be assumed as a function of electrical size of the EUT. The long term aim of the investigation is the estimation of the directivity of EUTs to correlate measurements of radiated emissions of electrically large EUTs in different test environments. By knowledge of directivity values and the measured total radiated power in an alternative test site, the maximum electric field strength of the EUT could be determined.

Key concepts: Directivity, Anechoic chamber, Effective radiated power, Enclosure, Acoustics, Radiation, Materials science, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of radiated emissions of an electrically large EUT: Simulation and experiment — Research Paper | ScholarLens