2013Unpublished venueRequires access

Method validation for the determination of hexavalent chromium in seawater and other matrices by colorimetric method / Yong Pui San

Pui San Yong

Open publisher page 0 citations

Abstract

The research project is about the method validation for the determination of hexavalent chromium in seawater and other matrices by colorimetric method. This method is validated by referring to the APHA 3500 B- Cr Colorimetric Method. The current colorimetric method of determination of hexavalent chromium in wastewater is carried out by using UV-VIS Spectrocopy. This method is developed to determine the trace level of hexavalent chromium up to a minimum 0.001 mg /L or 1 ppb of hexavalent chromium in seawater, river water and industrial effluent by using the Discrete Analyzer. The calibration range is within 0 to 0.25 mg Cr 6+/L or 250 ppb. In the method validation study, various concentration level of hexavalent chromium were spiked in various matrices where the recovery that were obtained within 88 % to 105 %. The instrument detection limit is 0.001 mg/L or 1 ppb. The measurement uncertainty is 0.05 ± 0.005 mg/L Cr 6+. The hexavalent chromium is determined colorimetrically by reaction with diphenylcarbazide in acid solution where the red-violet color of unknown composition will be produced. The absorbance is measured at 550 nm.

About this research paper

What this paper is about

The research project is about the method validation for the determination of hexavalent chromium in seawater and other matrices by colorimetric method. This method is validated by referring to the APHA 3500 B- Cr Colorimetric Method. The current colorimetric method of determination of hexavalent chromium in wastewater is carried out by using UV-VIS Spectrocopy. This method is developed to determine the trace level of hexavalent chromium up to a minimum 0.001 mg /L or 1 ppb of hexavalent chromium in seawater, river water and industrial effluent by using the Discrete Analyzer. The calibration range is within 0 to 0.25 mg Cr 6+/L or 250 ppb. In the method validation study, various concentration level of hexavalent chromium were spiked in various matrices where the recovery that were obtained within 88 % to 105 %. The instrument detection limit is 0.001 mg/L or 1 ppb. The measurement uncertainty is 0.05 ± 0.005 mg/L Cr 6+. The hexavalent chromium is determined colorimetrically by reaction with diphenylcarbazide in acid solution where the red-violet color of unknown composition will be produced. The absorbance is measured at 550 nm.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The research project is about the method validation for the determination of hexavalent chromium in seawater and other matrices by colorimetric method. This method is validated by referring to the APHA 3500 B- Cr Colorimetric Method. The current colorimetric method of determination of hexavalent chromium in wastewater is carried out by using UV-VIS Spectrocopy. This method is developed to determine the trace level of hexavalent chromium up to a minimum 0.001 mg /L or 1 ppb of hexavalent chromium in seawater, river water and industrial effluent by using the Discrete Analyzer. The calibration range is within 0 to 0.25 mg Cr 6+/L or 250 ppb. In the method validation study, various concentration level of hexavalent chromium were spiked in various matrices where the recovery that were obtained within 88 % to 105 %. The instrument detection limit is 0.001 mg/L or 1 ppb. The measurement uncertainty is 0.05 ± 0.005 mg/L Cr 6+. The hexavalent chromium is determined colorimetrically by reaction with diphenylcarbazide in acid solution where the red-violet color of unknown composition will be produced. The absorbance is measured at 550 nm.

Key concepts: Hexavalent chromium, Chromium, Seawater, Absorbance, Detection limit, Chemistry, Wastewater, Effluent

Related papers

Back to paper searchBrowse research topicsOriginal source
Method validation for the determination of hexavalent chromium in seawater and other matrices by colorimetric method / Yong Pui San — Research Paper | ScholarLens