Performance comparison of three-level and multi-level for Grid-connected photovoltaic systems

Chaiyant Boonmee, Pakorn Somboonkit, Napat Watjanatepin

Open publisher page 5 citations

Abstract

The most Grid-connected inverters for photovoltaic (PV) system use the three-level grid-connected inverter, which generates the three voltage level at the output of inverter. It can inject the sinusoidal current to utility grid through a set of filter as shown in Fig. 1. Even though, the three-level grid-connected inverter can be operated in high efficiency, but it still has some drawback, such as, the high total harmonic distortion (THD) of output voltage, the high switching power losses cause by high switching frequency in order to reduce the filter size, and power losses cause by mismatching of PV module power in the same PV string. The cascaded H-bridge multi-level inverter topology is an important choice to reduce some drawback of the three-level grid-connected inverter for PV system as shown in Fig.2. This paper presents the comparison studies the performance of using three-level and cascaded H-bridge multi-level inverter topologies for grid-connected PV system. The both inverter topologies have to operate as a single-phase grid-connected inverter in the same condition of filter size and under the IEEE standard of lower 5% of total harmonic distortion of grid current. The compared performance indicators consist of the grid injected power while the irradiation is changed in two cases (The same size and different size of PV power changing between two sets of PV string). The both systems have to be tested in the same testing condition. The MATLAB/SIMULINK simulation results are verified the accuracy of the both topologies performance.

About this research paper

What this paper is about

The most Grid-connected inverters for photovoltaic (PV) system use the three-level grid-connected inverter, which generates the three voltage level at the output of inverter. It can inject the sinusoidal current to utility grid through a set of filter as shown in Fig. 1. Even though, the three-level grid-connected inverter can be operated in high efficiency, but it still has some drawback, such as, the high total harmonic distortion (THD) of output voltage, the high switching power losses cause by high switching frequency in order to reduce the filter size, and power losses cause by mismatching of PV module power in the same PV string. The cascaded H-bridge multi-level inverter topology is an important choice to reduce some drawback of the three-level grid-connected inverter for PV system as shown in Fig.2. This paper presents the comparison studies the performance of using three-level and cascaded H-bridge multi-level inverter topologies for grid-connected PV system. The both inverter topologies have to operate as a single-phase grid-connected inverter in the same condition of filter size and under the IEEE standard of lower 5% of total harmonic distortion of grid current. The compared performance indicators consist of the grid injected power while the irradiation is changed in two cases (The same size and different size of PV power changing between two sets of PV string). The both systems have to be tested in the same testing condition. The MATLAB/SIMULINK simulation results are verified the accuracy of the both topologies performance.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The most Grid-connected inverters for photovoltaic (PV) system use the three-level grid-connected inverter, which generates the three voltage level at the output of inverter. It can inject the sinusoidal current to utility grid through a set of filter as shown in Fig. 1. Even though, the three-level grid-connected inverter can be operated in high efficiency, but it still has some drawback, such as, the high total harmonic distortion (THD) of output voltage, the high switching power losses cause by high switching frequency in order to reduce the filter size, and power losses cause by mismatching of PV module power in the same PV string. The cascaded H-bridge multi-level inverter topology is an important choice to reduce some drawback of the three-level grid-connected inverter for PV system as shown in Fig.2. This paper presents the comparison studies the performance of using three-level and cascaded H-bridge multi-level inverter topologies for grid-connected PV system. The both inverter topologies have to operate as a single-phase grid-connected inverter in the same condition of filter size and under the IEEE standard of lower 5% of total harmonic distortion of grid current. The compared performance indicators consist of the grid injected power while the irradiation is changed in two cases (The same size and different size of PV power changing between two sets of PV string). The both systems have to be tested in the same testing condition. The MATLAB/SIMULINK simulation results are verified the accuracy of the both topologies performance.

Key concepts: Photovoltaic system, Total harmonic distortion, Inverter, Maximum power point tracking, Grid-connected photovoltaic power system, Topology (electrical circuits), Grid-tie inverter, Computer science