Optimization of Headspace Solid Phase Microextraction Procedure for Trace Analysis of Toluene
Hamidreza Heidari, Seyed Jamaleddin Shahtaheri, Farideh Golbabaei, Mahmood Alimohammadi, Abbas Rahimi-Froushani
Abstract
Hamidreza Heidari, Seyed Jamaleddin Shahtaheri, Farideh Golbabaei, Mahmood Alimohammadi, Abbas Rahimi-Froushani
Abstract
This study describes optimization of headspace solid phase microextraction followed by gas chromatography equipped with a flame ionization detector for toluene at trace level in spiked urine. The parameters affecting the extraction and gas chromatographic determination of analytes were studied: extraction time and temperature; desorption time and temperature; addition of NaCl; and pH, volume and agitation of the sample. Optimized headspace extraction was carried out at 30 degrees C for 6 min in the presence of 0.2 g.m(-1)of NaCl in the sample solution. Also, sample volume and sample pH were optimized at 5 ml and 7 (neutral pH), respectively. Desorption of the analytes was carried out at 250 degrees C for 60 s. The optimized procedure was validated with 3 different pools of spiked urine; it showed good reproducibility over 6 consecutive days and 6 within-day experiments. The study also determined the accuracy, linearity and detection limits of this method.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study describes optimization of headspace solid phase microextraction followed by gas chromatography equipped with a flame ionization detector for toluene at trace level in spiked urine. The parameters affecting the extraction and gas chromatographic determination of analytes were studied: extraction time and temperature; desorption time and temperature; addition of NaCl; and pH, volume and agitation of the sample. Optimized headspace extraction was carried out at 30 degrees C for 6 min in the presence of 0.2 g.m(-1)of NaCl in the sample solution. Also, sample volume and sample pH were optimized at 5 ml and 7 (neutral pH), respectively. Desorption of the analytes was carried out at 250 degrees C for 60 s. The optimized procedure was validated with 3 different pools of spiked urine; it showed good reproducibility over 6 consecutive days and 6 within-day experiments. The study also determined the accuracy, linearity and detection limits of this method.
Key concepts: Chromatography, Solid-phase microextraction, Toluene, Extraction (chemistry), Flame ionization detector, Analyte, Reproducibility, Desorption