1989•Journal of the Korean Chemical SocietyRequires access

Study on the Ion Exchange Mechanisms of Rare Earth Elements in Several Elution Types (II)

Ki-Won Cha, Sung Wook Hong

Open publisher page 0 citations

Abstract

The elution mechanism of rare earth elements in cation exchange resin which was substituted with as a retaining ion had been investigated. Rare earths or rare earths-EDTA complex solution was loaded on the top of resin bed and eluted with 0.0269M EDTA solution. When the rare earth-EDTA complex was adsorbed on the resin form, retaining ion was complexed with EDTA and liberated rare earths was adsorbed in the resin again. Adsorbed rare earths in resin phase could be eluted by the complexation reaction with EDTA eluent. On resin form, the rare earth-EDTA complex which had negative charge could not adsorbed on the cation exchange resin because the complexation reaction between and EDTA was impossible. So the elution time was much shorter than in resin form. When the rare earths solution was loaded on the resin form bed, rare earths was adsorbed in the resin and the retaining ion was liberated. Adsorbed rare earths in resin bed was exchanged by EDTA eluent forming rare earths-EDTA complex, and eluted through these processes. On resin form, rare earths loaded was adsorbed by exchange reaction with . As the EDTA eluent was added, rare earths was liberated from resin forming negatively charged rare earth-EDTA complex and eluted without any exchange reaction. So the elution time was greatly shortened and there was no metallic ion except rare earths in effluent. When the was used as retaining ion, the pH of efflent was decreased seriousely because the liberated from EDTA molecule.

About this research paper

What this paper is about

The elution mechanism of rare earth elements in cation exchange resin which was substituted with as a retaining ion had been investigated. Rare earths or rare earths-EDTA complex solution was loaded on the top of resin bed and eluted with 0.0269M EDTA solution. When the rare earth-EDTA complex was adsorbed on the resin form, retaining ion was complexed with EDTA and liberated rare earths was adsorbed in the resin again. Adsorbed rare earths in resin phase could be eluted by the complexation reaction with EDTA eluent. On resin form, the rare earth-EDTA complex which had negative charge could not adsorbed on the cation exchange resin because the complexation reaction between and EDTA was impossible. So the elution time was much shorter than in resin form. When the rare earths solution was loaded on the resin form bed, rare earths was adsorbed in the resin and the retaining ion was liberated. Adsorbed rare earths in resin bed was exchanged by EDTA eluent forming rare earths-EDTA complex, and eluted through these processes. On resin form, rare earths loaded was adsorbed by exchange reaction with . As the EDTA eluent was added, rare earths was liberated from resin forming negatively charged rare earth-EDTA complex and eluted without any exchange reaction. So the elution time was greatly shortened and there was no metallic ion except rare earths in effluent. When the was used as retaining ion, the pH of efflent was decreased seriousely because the liberated from EDTA molecule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The elution mechanism of rare earth elements in cation exchange resin which was substituted with as a retaining ion had been investigated. Rare earths or rare earths-EDTA complex solution was loaded on the top of resin bed and eluted with 0.0269M EDTA solution. When the rare earth-EDTA complex was adsorbed on the resin form, retaining ion was complexed with EDTA and liberated rare earths was adsorbed in the resin again. Adsorbed rare earths in resin phase could be eluted by the complexation reaction with EDTA eluent. On resin form, the rare earth-EDTA complex which had negative charge could not adsorbed on the cation exchange resin because the complexation reaction between and EDTA was impossible. So the elution time was much shorter than in resin form. When the rare earths solution was loaded on the resin form bed, rare earths was adsorbed in the resin and the retaining ion was liberated. Adsorbed rare earths in resin bed was exchanged by EDTA eluent forming rare earths-EDTA complex, and eluted through these processes. On resin form, rare earths loaded was adsorbed by exchange reaction with . As the EDTA eluent was added, rare earths was liberated from resin forming negatively charged rare earth-EDTA complex and eluted without any exchange reaction. So the elution time was greatly shortened and there was no metallic ion except rare earths in effluent. When the was used as retaining ion, the pH of efflent was decreased seriousely because the liberated from EDTA molecule.

Key concepts: Elution, Chemistry, Ion-exchange resin, Adsorption, Column chromatography, Ion exchange, Inorganic chemistry, Rare earth

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Ion Exchange Mechanisms of Rare Earth Elements in Several Elution Types (II) — Research Paper | ScholarLens