1980NASA STI Repository (National Aeronautics and Space Administration)Open access

Performance of single-stage axial-flow transonic compressor with rotor and stator aspect ratios of 1.19 and 1.26 respectively, and with design pressure ratio of 2.05

R. D. Moore, L. Reid

Open full text 142 citations

Abstract

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range for speeds from 50 to 100 percent of design. The stage was designed for a pressure ratio of 2.05 at a flow of 20.2 kg/sec and a tip speed of 455 m/sec. At design speed the rotor and stage achieved peak efficiencies of 0.849 and 0.831, respectively, at the minimum flow condition. The stage stall point occurred at a flow higher than the design flow.

Open-access reader

About this research paper

What this paper is about

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range for speeds from 50 to 100 percent of design. The stage was designed for a pressure ratio of 2.05 at a flow of 20.2 kg/sec and a tip speed of 455 m/sec. At design speed the rotor and stage achieved peak efficiencies of 0.849 and 0.831, respectively, at the minimum flow condition. The stage stall point occurred at a flow higher than the design flow.

Why it matters

OpenAlex reports 142 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range for speeds from 50 to 100 percent of design. The stage was designed for a pressure ratio of 2.05 at a flow of 20.2 kg/sec and a tip speed of 455 m/sec. At design speed the rotor and stage achieved peak efficiencies of 0.849 and 0.831, respectively, at the minimum flow condition. The stage stall point occurred at a flow higher than the design flow.

Key concepts: Stall (fluid mechanics), Overall pressure ratio, Transonic, Axial compressor, Gas compressor, Stator, Materials science, Rotor (electric)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of single-stage axial-flow transonic compressor with rotor and stator aspect ratios of 1.19 and 1.26 respectively, and with design pressure ratio of 2.05 — Research Paper | ScholarLens