1997Volume 4: Manufacturing Materials and Metallurgy; Ceramics; Structures and Dynamics; Controls, Diagnostics and Instrumentation; Education; IGTI Scholar AwardOpen access

Active Stabilization of Rotating Stall and Surge in a Transonic Single Stage Axial Compressor

Harald J. Weigl, James D. Paduano, Luc G. Fréchette, Alan H. Epstein, E. M. Greitzer, Michelle M. Bright, A. J. Strazisar

Open full text 191 citations

Abstract

Rotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved a 11% and 3.5% reduction in stalling mass flow respectively, with injection adding 3.6% of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip, of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the pre-stall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the pre-stall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately 10 rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150% of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes which comprise the first three harmonic perturbations in this transonic region of operation.

About this research paper

What this paper is about

Rotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved a 11% and 3.5% reduction in stalling mass flow respectively, with injection adding 3.6% of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip, of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the pre-stall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the pre-stall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately 10 rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150% of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes which comprise the first three harmonic perturbations in this transonic region of operation.

Why it matters

OpenAlex reports 191 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Rotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved a 11% and 3.5% reduction in stalling mass flow respectively, with injection adding 3.6% of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip, of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the pre-stall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the pre-stall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately 10 rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150% of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes which comprise the first three harmonic perturbations in this transonic region of operation.

Key concepts: Stall (fluid mechanics), Axial compressor, Gas compressor, Transonic, Mach number, Mechanics, Control theory (sociology), Surge

Related papers

Back to paper searchBrowse research topicsOriginal source
Active Stabilization of Rotating Stall and Surge in a Transonic Single Stage Axial Compressor — Research Paper | ScholarLens