2002•力学学报:英文版Requires access

3C DUCT DESIGN METHOD

Huan-RueiShiu, Feng-ChuOu, Sih-LiChen

Open publisher page 0 citations

Abstract

A new 3C duct design method is proposed for designing a high quality, energy-efficiency cost-effective air duct system. It not only considers the demand of volume flow rate, but also takes into consideration a number of issues including system pressure balance, noise, vibration, space limitation and total system cost. This new method comprises three major calculation procedures:initial computer-aided design (CAD), computer-aided simulation (CAS) and correction processes (CP). An example is presented in this study to understand the characteristics of 3C method. It shows that 3C duct design method provides a simple computation procedure for an optimum air duct system. It also shortens the design schedule, prevents human calculation errors, and reduces the dependence on designer experience. In addition to apply in a new duct system design, 3C duct design method is also a powerful design tool for the expansion of an existing duct system.

About this research paper

What this paper is about

A new 3C duct design method is proposed for designing a high quality, energy-efficiency cost-effective air duct system. It not only considers the demand of volume flow rate, but also takes into consideration a number of issues including system pressure balance, noise, vibration, space limitation and total system cost. This new method comprises three major calculation procedures:initial computer-aided design (CAD), computer-aided simulation (CAS) and correction processes (CP). An example is presented in this study to understand the characteristics of 3C method. It shows that 3C duct design method provides a simple computation procedure for an optimum air duct system. It also shortens the design schedule, prevents human calculation errors, and reduces the dependence on designer experience. In addition to apply in a new duct system design, 3C duct design method is also a powerful design tool for the expansion of an existing duct system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new 3C duct design method is proposed for designing a high quality, energy-efficiency cost-effective air duct system. It not only considers the demand of volume flow rate, but also takes into consideration a number of issues including system pressure balance, noise, vibration, space limitation and total system cost. This new method comprises three major calculation procedures:initial computer-aided design (CAD), computer-aided simulation (CAS) and correction processes (CP). An example is presented in this study to understand the characteristics of 3C method. It shows that 3C duct design method provides a simple computation procedure for an optimum air duct system. It also shortens the design schedule, prevents human calculation errors, and reduces the dependence on designer experience. In addition to apply in a new duct system design, 3C duct design method is also a powerful design tool for the expansion of an existing duct system.

Key concepts: Duct (anatomy), Computer science, Computation, Systems design, Common Duct, Simulation, Algorithm, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
3C DUCT DESIGN METHOD — Research Paper | ScholarLens