Repowering cuts air pollution, improves station`s efficiency
K. Daledda
Abstract
K. Daledda
Abstract
This article reports that after rehab plans for 30-yr-old boilers proved untenable, gas-fired combined cycle, with the existing steam turbines retained, was the choice. Large reductions in NO{sub x}, SO{sub 2}, and CO{sub 2} will be benefits. A unique closed-loop cooling system reduces impact on environment in several ways. When the boilers of existing steam Units 1 and 2 at Bergen generating station were in need of major overhaul, Public Service Electric and Gas Co (PSE and G) began analysis of alternatives to the rehab work. Combined-cycle repowering offered several advantages, including improvement in efficiency -- from 28 to 44% -- and important reduction in air-pollutant and thermal emissions. Continued use of a large portion of the existing plant and infrastructure meant added economic advantages for repowering over construction of a new plant. The project which will come on line in 1995, increases station output from 570MW to 650MW. The station operates as a load-following unit, with expected capacity factor of 65% compared with 30% for the old station. For minimum load, one gas turbine (GT) runs at 100% load, with the steam turbine operational. The GTs operate independently, and the ramp up to 100% load is done immediately, whichmore » gives best efficiency and reduces air emissions.« less
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This article reports that after rehab plans for 30-yr-old boilers proved untenable, gas-fired combined cycle, with the existing steam turbines retained, was the choice. Large reductions in NO{sub x}, SO{sub 2}, and CO{sub 2} will be benefits. A unique closed-loop cooling system reduces impact on environment in several ways. When the boilers of existing steam Units 1 and 2 at Bergen generating station were in need of major overhaul, Public Service Electric and Gas Co (PSE and G) began analysis of alternatives to the rehab work. Combined-cycle repowering offered several advantages, including improvement in efficiency -- from 28 to 44% -- and important reduction in air-pollutant and thermal emissions. Continued use of a large portion of the existing plant and infrastructure meant added economic advantages for repowering over construction of a new plant. The project which will come on line in 1995, increases station output from 570MW to 650MW. The station operates as a load-following unit, with expected capacity factor of 65% compared with 30% for the old station. For minimum load, one gas turbine (GT) runs at 100% load, with the steam turbine operational. The GTs operate independently, and the ramp up to 100% load is done immediately, whichmore » gives best efficiency and reduces air emissions.« less
Key concepts: Combined cycle, Steam turbine, Engineering, Thermal power station, Steam-electric power station, Power station, Air pollution, Work (physics)