2005•PubMedRequires access

Determination of oxytetracycline in salmon by liquid chromatography with metal-chelate fluorescence detection.

Heidi S Rupp, Collin R. Anderson

Open publisher page 10 citations

Abstract

A liquid chromatography (LC) method is described for the determination of oxytetracycline (OTC) in farmed Atlantic salmon muscle tissue. The method involves homogenization of salmon tissue, extraction of OTC into Mcllvaine-EDTA buffer, acid precipitation of proteins, cleanup through tandem solid-phase extraction cartridges (Strata-X and aminopropyl), elution with mobile phase containing slightly alkaline buffer and Mg2+, and LC separation with metal-chelate induced fluorescence detection. Salmon tissue was fortified with 0.10, 0.25, 0.50, 0.75, and 1.0 microg/g (ppm) oxytetracycline. Average absolute recoveries were 84, 76, 70, 76, and 85%, respectively, with relative standard deviation (RSD) values all less than 9%. The interassay average recovery was 78%, with a 4.2% RSD. Determination was based on a standard graph using peak areas with standard solutions equivalent to 0.0625, 0.125, 0.25, 0.50, and 1.0 ppm in tissue. A set of 5 matrix controls (unfortified salmon tissue) were also analyzed, in which no OTC was detected. The lowest standard was used as the limit of quantitation.

About this research paper

What this paper is about

A liquid chromatography (LC) method is described for the determination of oxytetracycline (OTC) in farmed Atlantic salmon muscle tissue. The method involves homogenization of salmon tissue, extraction of OTC into Mcllvaine-EDTA buffer, acid precipitation of proteins, cleanup through tandem solid-phase extraction cartridges (Strata-X and aminopropyl), elution with mobile phase containing slightly alkaline buffer and Mg2+, and LC separation with metal-chelate induced fluorescence detection. Salmon tissue was fortified with 0.10, 0.25, 0.50, 0.75, and 1.0 microg/g (ppm) oxytetracycline. Average absolute recoveries were 84, 76, 70, 76, and 85%, respectively, with relative standard deviation (RSD) values all less than 9%. The interassay average recovery was 78%, with a 4.2% RSD. Determination was based on a standard graph using peak areas with standard solutions equivalent to 0.0625, 0.125, 0.25, 0.50, and 1.0 ppm in tissue. A set of 5 matrix controls (unfortified salmon tissue) were also analyzed, in which no OTC was detected. The lowest standard was used as the limit of quantitation.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A liquid chromatography (LC) method is described for the determination of oxytetracycline (OTC) in farmed Atlantic salmon muscle tissue. The method involves homogenization of salmon tissue, extraction of OTC into Mcllvaine-EDTA buffer, acid precipitation of proteins, cleanup through tandem solid-phase extraction cartridges (Strata-X and aminopropyl), elution with mobile phase containing slightly alkaline buffer and Mg2+, and LC separation with metal-chelate induced fluorescence detection. Salmon tissue was fortified with 0.10, 0.25, 0.50, 0.75, and 1.0 microg/g (ppm) oxytetracycline. Average absolute recoveries were 84, 76, 70, 76, and 85%, respectively, with relative standard deviation (RSD) values all less than 9%. The interassay average recovery was 78%, with a 4.2% RSD. Determination was based on a standard graph using peak areas with standard solutions equivalent to 0.0625, 0.125, 0.25, 0.50, and 1.0 ppm in tissue. A set of 5 matrix controls (unfortified salmon tissue) were also analyzed, in which no OTC was detected. The lowest standard was used as the limit of quantitation.

Key concepts: Oxytetracycline, Chromatography, Chemistry, Detection limit, Elution, Homogenization (climate), Extraction (chemistry), Solid phase extraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of oxytetracycline in salmon by liquid chromatography with metal-chelate fluorescence detection. — Research Paper | ScholarLens