[Determination of thirteen metal elements in the plant Foeniculum vulgare Mill. by flame atomic absorption spectrophotometry].
Guo-Qing Xue, Qing Liu, Yuqi Han, Hui-guang Wei, Ting Dong
Abstract
Guo-Qing Xue, Qing Liu, Yuqi Han, Hui-guang Wei, Ting Dong
Abstract
The objective of the paper is to determine the amount of metal elements of Na, K, Mg, Ca, Cu, Zn, Mn, Fe, Co, Ni, Cd, Cr and Pb in the planted Foeniculum vulgare Mill. by flame atomic absorption spectrophotometry (FAAS), after the cinefaction and the digestion with HNO3-HClO4 (phi 4:1) at 90-95 degrees C and normal pressure. The optimum parameters of FAAS and the effects of solution medium on the results were investigated. The analytical results show that the amount of Na, K, Mg, Ca, Mn, Fe, Cu, Zn and Pb was 1508.7, 27653.0, 2036.0, 4848.1, 24.8, 323.5, 15.2, 23.7 and 10.8 microg x g(-1), respectively, and that of Co, Ni, Cd and Cr was not checked out in the samples. The recovery of standard addition is 97.45%-102.50%, the relative standard deviation (n=9) was 0.34%-2.77%. The characteristic method is quick, simple and convenient and the results are satisfactory.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The objective of the paper is to determine the amount of metal elements of Na, K, Mg, Ca, Cu, Zn, Mn, Fe, Co, Ni, Cd, Cr and Pb in the planted Foeniculum vulgare Mill. by flame atomic absorption spectrophotometry (FAAS), after the cinefaction and the digestion with HNO3-HClO4 (phi 4:1) at 90-95 degrees C and normal pressure. The optimum parameters of FAAS and the effects of solution medium on the results were investigated. The analytical results show that the amount of Na, K, Mg, Ca, Mn, Fe, Cu, Zn and Pb was 1508.7, 27653.0, 2036.0, 4848.1, 24.8, 323.5, 15.2, 23.7 and 10.8 microg x g(-1), respectively, and that of Co, Ni, Cd and Cr was not checked out in the samples. The recovery of standard addition is 97.45%-102.50%, the relative standard deviation (n=9) was 0.34%-2.77%. The characteristic method is quick, simple and convenient and the results are satisfactory.
Key concepts: Foeniculum, Atomic absorption spectroscopy, Chemistry, Metal, Analytical Chemistry (journal), Relative standard deviation, Spectrophotometry, Standard addition