1992American Journal of Clinical PathologyRequires access

Monoclonal Antibody to Pneumocystis carinii: Comparison with Silver Stain in Bronchial Lavage Specimens

Kevin S. Homer, Elizabeth L. Wiley, Alice L. Smith, Lola McCollough, Dorothy Clark, Stephen D. Nightingale, Frank Vuitch

Open publisher page 18 citations

Abstract

Monoclonal 3F6 anti-Pneumocystis carinii antibody (MAB-3F6) was used to stain cell blocks from 164 bronchial lavage specimens from patients with the acquired immune deficiency syndrome (AIDS) and AIDS-related complex and compared with slides stained with Grocott's modification of the Gomori methenamine silver stain. Pneumocystis organisms were present in 83 of 164 cases using MAB-3F6 stain, whereas Grocott's modified silver stain demonstrated Pneumocystis organisms in 48. MAB-3F6 demonstrated Pneumocystis organisms in 38 cases with negative silver stains, whereas silver stain identified Pneumocystis organisms in only three MAB-3F6-negative cases. Of 70 patients with clinical Pneumocystis pneumonia at the time of the specimen was obtained, 59 had MAB-3F6-positive specimens, whereas 39 had organisms detected using Grocott's modified silver stain. Of 37 patients without clinically apparent Pneumocystis pneumonia any time in their course, 4 had abundant organisms and 33 had negative stains with MAB-3F6. MAB-3F6 detected Pneumocystis organisms in 22 of 31 cases of Pneumocystis pneumonia that had no organisms identified using Grocott's silver stain (X2 = 5.76, P = 0.016). MAB-3F6 immunochemical staining is a more sensitive method than Grocott's modified silver stain to detect Pneumocystis organisms.

About this research paper

What this paper is about

Monoclonal 3F6 anti-Pneumocystis carinii antibody (MAB-3F6) was used to stain cell blocks from 164 bronchial lavage specimens from patients with the acquired immune deficiency syndrome (AIDS) and AIDS-related complex and compared with slides stained with Grocott's modification of the Gomori methenamine silver stain. Pneumocystis organisms were present in 83 of 164 cases using MAB-3F6 stain, whereas Grocott's modified silver stain demonstrated Pneumocystis organisms in 48. MAB-3F6 demonstrated Pneumocystis organisms in 38 cases with negative silver stains, whereas silver stain identified Pneumocystis organisms in only three MAB-3F6-negative cases. Of 70 patients with clinical Pneumocystis pneumonia at the time of the specimen was obtained, 59 had MAB-3F6-positive specimens, whereas 39 had organisms detected using Grocott's modified silver stain. Of 37 patients without clinically apparent Pneumocystis pneumonia any time in their course, 4 had abundant organisms and 33 had negative stains with MAB-3F6. MAB-3F6 detected Pneumocystis organisms in 22 of 31 cases of Pneumocystis pneumonia that had no organisms identified using Grocott's silver stain (X2 = 5.76, P = 0.016). MAB-3F6 immunochemical staining is a more sensitive method than Grocott's modified silver stain to detect Pneumocystis organisms.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Monoclonal 3F6 anti-Pneumocystis carinii antibody (MAB-3F6) was used to stain cell blocks from 164 bronchial lavage specimens from patients with the acquired immune deficiency syndrome (AIDS) and AIDS-related complex and compared with slides stained with Grocott's modification of the Gomori methenamine silver stain. Pneumocystis organisms were present in 83 of 164 cases using MAB-3F6 stain, whereas Grocott's modified silver stain demonstrated Pneumocystis organisms in 48. MAB-3F6 demonstrated Pneumocystis organisms in 38 cases with negative silver stains, whereas silver stain identified Pneumocystis organisms in only three MAB-3F6-negative cases. Of 70 patients with clinical Pneumocystis pneumonia at the time of the specimen was obtained, 59 had MAB-3F6-positive specimens, whereas 39 had organisms detected using Grocott's modified silver stain. Of 37 patients without clinically apparent Pneumocystis pneumonia any time in their course, 4 had abundant organisms and 33 had negative stains with MAB-3F6. MAB-3F6 detected Pneumocystis organisms in 22 of 31 cases of Pneumocystis pneumonia that had no organisms identified using Grocott's silver stain (X2 = 5.76, P = 0.016). MAB-3F6 immunochemical staining is a more sensitive method than Grocott's modified silver stain to detect Pneumocystis organisms.

Key concepts: Grocott's methenamine silver stain, Pneumocystis carinii, Stain, Silver stain, Pneumocystis pneumonia, Staining, Monoclonal antibody, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Monoclonal Antibody to Pneumocystis carinii: Comparison with Silver Stain in Bronchial Lavage Specimens — Research Paper | ScholarLens