High Resolution Spectroscopy with a Quantum Cascade Laser at 2.5 THz
Heinz-Wilhelm Hiibers, S. G. Pavlov, Heiko Richter, Alexei D. Semenov, Lukas Mahler, Alessandro Tredicucci, Harvey E. Beere, D. A. Ritchie
Abstract
Heinz-Wilhelm Hiibers, S. G. Pavlov, Heiko Richter, Alexei D. Semenov, Lukas Mahler, Alessandro Tredicucci, Harvey E. Beere, D. A. Ritchie
Abstract
The quantum cascade laser (QCL) is a powerful, narrow linewidth, and continuous wave source of terahertz radiation. We have characterized a 23 THz distributed feedback QCL with respect to linevvidth and frequency tunability. Both were found to be sufficiently good for high resolution gas phase spectroscopy. The QCL was implemented in a spectrometer for high resolution gas phase spectroscopy where the absolute frequency of the laser was determined by mixing its radiation with the radiation of a 2.5 THz optically pumped gas laser. The absolute frequency as well as the pressure broadening of a rotational transition of methanol at 2.519 THz was measured. The results demonstrate that THz QCLs are well suited for either direct absorption or heterodyne high resolution spectroscopy.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The quantum cascade laser (QCL) is a powerful, narrow linewidth, and continuous wave source of terahertz radiation. We have characterized a 23 THz distributed feedback QCL with respect to linevvidth and frequency tunability. Both were found to be sufficiently good for high resolution gas phase spectroscopy. The QCL was implemented in a spectrometer for high resolution gas phase spectroscopy where the absolute frequency of the laser was determined by mixing its radiation with the radiation of a 2.5 THz optically pumped gas laser. The absolute frequency as well as the pressure broadening of a rotational transition of methanol at 2.519 THz was measured. The results demonstrate that THz QCLs are well suited for either direct absorption or heterodyne high resolution spectroscopy.
Key concepts: Quantum cascade laser, Laser linewidth, Terahertz radiation, Spectroscopy, Laser, Heterodyne (poetry), Materials science, Optics