2009Unpublished venueRequires access

Study on the Fire Behaviour of Composite Beam with Loading and Unloading

Sungbae Kim, Chang-Nam Lee, Woochul Kim, Sang-Seup Kim

Open publisher page 0 citations

Abstract

In this study, the fire resistance performance of a simple support composite beam, which was sprayed with fire protection coatings, was evaluated. Primary valuables of the study are loading and unloading, shape of composite beam and metal lath of the web. The thickness of the fire protection coating to the three hour resistance is 40mm, but the fire resistance test was performed with 25mm coatings. The test result showed that TSC composit beams with 25mm fire protection coatings can resist on fire for three hours at the both loading and unloading tests. Average and maximum temperatures were less than and respectively, compared with the standard temperatures for fire resistance on the loading and unloading tests.

About this research paper

What this paper is about

In this study, the fire resistance performance of a simple support composite beam, which was sprayed with fire protection coatings, was evaluated. Primary valuables of the study are loading and unloading, shape of composite beam and metal lath of the web. The thickness of the fire protection coating to the three hour resistance is 40mm, but the fire resistance test was performed with 25mm coatings. The test result showed that TSC composit beams with 25mm fire protection coatings can resist on fire for three hours at the both loading and unloading tests. Average and maximum temperatures were less than and respectively, compared with the standard temperatures for fire resistance on the loading and unloading tests.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, the fire resistance performance of a simple support composite beam, which was sprayed with fire protection coatings, was evaluated. Primary valuables of the study are loading and unloading, shape of composite beam and metal lath of the web. The thickness of the fire protection coating to the three hour resistance is 40mm, but the fire resistance test was performed with 25mm coatings. The test result showed that TSC composit beams with 25mm fire protection coatings can resist on fire for three hours at the both loading and unloading tests. Average and maximum temperatures were less than and respectively, compared with the standard temperatures for fire resistance on the loading and unloading tests.

Key concepts: Materials science, Fire resistance, Composite material, Composite number, Beam (structure), Coating, Fire test, Fire performance

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Fire Behaviour of Composite Beam with Loading and Unloading — Research Paper | ScholarLens