1996BloodRequires access

The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria

SE Hall, WF Rosse

Open publisher page 228 citations

Abstract

We have characterized the erythrocytes, granulocytes, and platelets of 54 patients with paroxysmal nocturnal hemoglobinuria (PNH) with antibodies to glycosylphosphatidylinositol-anchored proteins (anti-CD55, anti-CD59, and anti-CD16) and flow cytometry to establish the usefulness of this technique in the diagnosis of this disorder. All patients demonstrated either completely (PNH III) or partially (PNH II) deficient red cells and granulocytes. Anti-CD59 best demonstrated PNH II red cells, which were present in 50% of the patients. The proportion of abnormal granulocytes was usually greater than the proportion of abnormal red cells; 37% of the patients had >80% abnormal granulocytes. Anti-CD55 did not delineate the erythrocyte populations as well as did anti-CD59. Either anti-CD55 or anti-CD59 could be used equally well to analyze granulocytes; anti-CD16 did not demonstrate cells of partial deficiency. Platelets could not be used for detailed analysis as the normal and abnormal populations were not well distinguished. Flow cytometry of erythrocytes using anti-CD59 or of granulocytes using either anti-CD55 or anti-CD59 provides the most accurate technique for the diagnosis of paroxysmal nocturnal hemoglobinuria; it is clearly more specific, more quantitative, and more sensitive than the tests for PNH that depend upon hemolysis by complement (the acidified serum lysis [Ham] test, the sucrose lysis test, and the complement lysis sensitivity [CLS] test).

About this research paper

What this paper is about

We have characterized the erythrocytes, granulocytes, and platelets of 54 patients with paroxysmal nocturnal hemoglobinuria (PNH) with antibodies to glycosylphosphatidylinositol-anchored proteins (anti-CD55, anti-CD59, and anti-CD16) and flow cytometry to establish the usefulness of this technique in the diagnosis of this disorder. All patients demonstrated either completely (PNH III) or partially (PNH II) deficient red cells and granulocytes. Anti-CD59 best demonstrated PNH II red cells, which were present in 50% of the patients. The proportion of abnormal granulocytes was usually greater than the proportion of abnormal red cells; 37% of the patients had >80% abnormal granulocytes. Anti-CD55 did not delineate the erythrocyte populations as well as did anti-CD59. Either anti-CD55 or anti-CD59 could be used equally well to analyze granulocytes; anti-CD16 did not demonstrate cells of partial deficiency. Platelets could not be used for detailed analysis as the normal and abnormal populations were not well distinguished. Flow cytometry of erythrocytes using anti-CD59 or of granulocytes using either anti-CD55 or anti-CD59 provides the most accurate technique for the diagnosis of paroxysmal nocturnal hemoglobinuria; it is clearly more specific, more quantitative, and more sensitive than the tests for PNH that depend upon hemolysis by complement (the acidified serum lysis [Ham] test, the sucrose lysis test, and the complement lysis sensitivity [CLS] test).

Why it matters

OpenAlex reports 228 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have characterized the erythrocytes, granulocytes, and platelets of 54 patients with paroxysmal nocturnal hemoglobinuria (PNH) with antibodies to glycosylphosphatidylinositol-anchored proteins (anti-CD55, anti-CD59, and anti-CD16) and flow cytometry to establish the usefulness of this technique in the diagnosis of this disorder. All patients demonstrated either completely (PNH III) or partially (PNH II) deficient red cells and granulocytes. Anti-CD59 best demonstrated PNH II red cells, which were present in 50% of the patients. The proportion of abnormal granulocytes was usually greater than the proportion of abnormal red cells; 37% of the patients had >80% abnormal granulocytes. Anti-CD55 did not delineate the erythrocyte populations as well as did anti-CD59. Either anti-CD55 or anti-CD59 could be used equally well to analyze granulocytes; anti-CD16 did not demonstrate cells of partial deficiency. Platelets could not be used for detailed analysis as the normal and abnormal populations were not well distinguished. Flow cytometry of erythrocytes using anti-CD59 or of granulocytes using either anti-CD55 or anti-CD59 provides the most accurate technique for the diagnosis of paroxysmal nocturnal hemoglobinuria; it is clearly more specific, more quantitative, and more sensitive than the tests for PNH that depend upon hemolysis by complement (the acidified serum lysis [Ham] test, the sucrose lysis test, and the complement lysis sensitivity [CLS] test).

Key concepts: Paroxysmal nocturnal hemoglobinuria, CD59, Hemoglobinuria, Flow cytometry, Hemolysis, Monoclonal antibody, Immunology, Antibody

Related papers

Back to paper searchBrowse research topicsOriginal source
The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria — Research Paper | ScholarLens