2012PORTO Publications Open Repository TOrino (Politecnico di Torino)Requires access

An experimental and numerical analysis of daylighting performance for an office building

Giorgia Nardini, M. Paroncini, R.M. Valerio

Open publisher page 1 citations

Abstract

The urgency of increasing energy efficiency in new building design and retrofits has moved lighting simulation into a central role in sustainable lighting design. In fact, good daylighting design can result in energy savings and can shift peak electrical demand during afternoon hours when daylight availability levels and utility rates are high. The shape of the building and its orientation, the reflectances of the building surfaces and the glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and the associated pollution sources, reduce peak demand, enhance daylighting performance, and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim is to analyse the illuminance distribution and some investigations have also been made with regard to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and a sky simulator. The numerical results were obtained through the ray-tracing program Radiance that accurately predicts the light levels and that produces photo realistic images of the architectural space in all sky conditions: illuminance values are obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed

About this research paper

What this paper is about

The urgency of increasing energy efficiency in new building design and retrofits has moved lighting simulation into a central role in sustainable lighting design. In fact, good daylighting design can result in energy savings and can shift peak electrical demand during afternoon hours when daylight availability levels and utility rates are high. The shape of the building and its orientation, the reflectances of the building surfaces and the glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and the associated pollution sources, reduce peak demand, enhance daylighting performance, and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim is to analyse the illuminance distribution and some investigations have also been made with regard to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and a sky simulator. The numerical results were obtained through the ray-tracing program Radiance that accurately predicts the light levels and that produces photo realistic images of the architectural space in all sky conditions: illuminance values are obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The urgency of increasing energy efficiency in new building design and retrofits has moved lighting simulation into a central role in sustainable lighting design. In fact, good daylighting design can result in energy savings and can shift peak electrical demand during afternoon hours when daylight availability levels and utility rates are high. The shape of the building and its orientation, the reflectances of the building surfaces and the glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and the associated pollution sources, reduce peak demand, enhance daylighting performance, and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim is to analyse the illuminance distribution and some investigations have also been made with regard to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and a sky simulator. The numerical results were obtained through the ray-tracing program Radiance that accurately predicts the light levels and that produces photo realistic images of the architectural space in all sky conditions: illuminance values are obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed

Key concepts: Daylighting, Daylight, Illuminance, Radiance, Glazing, Architectural engineering, Sky, Building design

Related papers

Back to paper searchBrowse research topicsOriginal source
An experimental and numerical analysis of daylighting performance for an office building — Research Paper | ScholarLens