1996•PubMedRequires access

Reverse transcription/polymerase chain reaction (RT/PCR) amplification of very small numbers of transcripts: the risk in misinterpreting negative results.

J V Melo, X H Yan, Joana Diamond, F Lin, Nicholas C.P. Cross, John M. Goldman

Open publisher page 45 citations

Abstract

Technical modifications of the reverse-transcription/polymerase chain reaction (RT/PCR) amplification method now permit its use to detect amplified products from as few as one abnormal cell, either isolated or mixed with a larger number of normal cells. We studied the reproducibility of such results using as targets low numbers of cells from chronic myeloid leukaemia (CML) patients and CML cell lines in quintuplicate two-step RT/PCR designed to amplify BCR-ABL sequences. When one K562 or KYO1 cell was diluted in 10(3) non-CML HL60 cells, an amplification product was obtained in each test; at greater dilutions BCR-ABL transcripts were detected erratically. Titration of cDNA synthesised from 5 x 10(7) cells from four CML patients showed that whereas positive BCR-ABL sequences could be amplified in some tests starting with as little as a 1 in 10(7) dilution of cDNA template (corresponding to 5-10 cells), the dilution threshold for reproducible amplification was around 1 to 5 in 10(5) (100-500 cells). Quantitative PCR analysis revealed that reactions from 1 in 10(7) diluted cDNA contained less than 10 BCR-ABL transcripts as the starting template. The stochastic nature of the amplification from such small numbers of transcripts was illustrated by results of 10 replicate PCR tests on cDNA from a patient expressing both b3a2 and b2a2 transcripts: dilutions of cDNA up to 1 in 10(5) yielded dual transcript amplification in all 10 tests, but the 1 in 10(7) cDNA dilution resulted in b3a2 and b2a2 products in three tests, b3a2 only in three, b2a2 only in one and no amplification in three tests. We conclude that this 'sampling effect' may yield false-negative results and thus misinterpretation of data regarding assessment of gene expression when the quantity of target material available for study is very small.

About this research paper

What this paper is about

Technical modifications of the reverse-transcription/polymerase chain reaction (RT/PCR) amplification method now permit its use to detect amplified products from as few as one abnormal cell, either isolated or mixed with a larger number of normal cells. We studied the reproducibility of such results using as targets low numbers of cells from chronic myeloid leukaemia (CML) patients and CML cell lines in quintuplicate two-step RT/PCR designed to amplify BCR-ABL sequences. When one K562 or KYO1 cell was diluted in 10(3) non-CML HL60 cells, an amplification product was obtained in each test; at greater dilutions BCR-ABL transcripts were detected erratically. Titration of cDNA synthesised from 5 x 10(7) cells from four CML patients showed that whereas positive BCR-ABL sequences could be amplified in some tests starting with as little as a 1 in 10(7) dilution of cDNA template (corresponding to 5-10 cells), the dilution threshold for reproducible amplification was around 1 to 5 in 10(5) (100-500 cells). Quantitative PCR analysis revealed that reactions from 1 in 10(7) diluted cDNA contained less than 10 BCR-ABL transcripts as the starting template. The stochastic nature of the amplification from such small numbers of transcripts was illustrated by results of 10 replicate PCR tests on cDNA from a patient expressing both b3a2 and b2a2 transcripts: dilutions of cDNA up to 1 in 10(5) yielded dual transcript amplification in all 10 tests, but the 1 in 10(7) cDNA dilution resulted in b3a2 and b2a2 products in three tests, b3a2 only in three, b2a2 only in one and no amplification in three tests. We conclude that this 'sampling effect' may yield false-negative results and thus misinterpretation of data regarding assessment of gene expression when the quantity of target material available for study is very small.

Why it matters

OpenAlex reports 45 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Technical modifications of the reverse-transcription/polymerase chain reaction (RT/PCR) amplification method now permit its use to detect amplified products from as few as one abnormal cell, either isolated or mixed with a larger number of normal cells. We studied the reproducibility of such results using as targets low numbers of cells from chronic myeloid leukaemia (CML) patients and CML cell lines in quintuplicate two-step RT/PCR designed to amplify BCR-ABL sequences. When one K562 or KYO1 cell was diluted in 10(3) non-CML HL60 cells, an amplification product was obtained in each test; at greater dilutions BCR-ABL transcripts were detected erratically. Titration of cDNA synthesised from 5 x 10(7) cells from four CML patients showed that whereas positive BCR-ABL sequences could be amplified in some tests starting with as little as a 1 in 10(7) dilution of cDNA template (corresponding to 5-10 cells), the dilution threshold for reproducible amplification was around 1 to 5 in 10(5) (100-500 cells). Quantitative PCR analysis revealed that reactions from 1 in 10(7) diluted cDNA contained less than 10 BCR-ABL transcripts as the starting template. The stochastic nature of the amplification from such small numbers of transcripts was illustrated by results of 10 replicate PCR tests on cDNA from a patient expressing both b3a2 and b2a2 transcripts: dilutions of cDNA up to 1 in 10(5) yielded dual transcript amplification in all 10 tests, but the 1 in 10(7) cDNA dilution resulted in b3a2 and b2a2 products in three tests, b3a2 only in three, b2a2 only in one and no amplification in three tests. We conclude that this 'sampling effect' may yield false-negative results and thus misinterpretation of data regarding assessment of gene expression when the quantity of target material available for study is very small.

Key concepts: Complementary DNA, Serial dilution, Reverse transcriptase, Molecular biology, Biology, Polymerase chain reaction, Reverse transcription polymerase chain reaction, Primer dimer

Related papers

Back to paper searchBrowse research topicsOriginal source
Reverse transcription/polymerase chain reaction (RT/PCR) amplification of very small numbers of transcripts: the risk in misinterpreting negative results. — Research Paper | ScholarLens