Torque ripple reduction in direct torque controlled induction motor drive by using fuzzy controller

Venkata RamaKrishna G

Open publisher page 0 citations

Abstract

Direct torque control(DTC) of an induction motor fed by a voltage source inverter is a simple scheme that does not need long computation time and can be implanted without mechanical speed sensors and is insensitive to parameter variations. In principle, the motor terminal voltages and currents are sampled and used to estimate the motor flux and torque. Based on estimates of the flux position and the instantaneous errors in torque and stator flux magnitude, a voltage vector is selected to restrict the torque and the flux errors within their respective torque and flux hysteresis bands. In the conventional DTC, the selected voltage vector is applied for the whole switching period regardless of the magnitude of the torque error. This can result in high torque ripple. A better drive performance can be achieved by varying the duty ratio of the selected voltage vector during each switching period according to the magnitude of the torque error and position of the stator flux. A duty ratio control scheme for an inverter-fed induction machine using DTC method is presented in this thesis. The use of the duty ratio control resulted in improved steady state torque response, with less torque ripple than the conventional DTC. Fuzzy logic control was used to implement the duty ratio controller. The effectiveness of the duty ratio method was verified by simulation using MATLAB/SIMULINK®.

About this research paper

What this paper is about

Direct torque control(DTC) of an induction motor fed by a voltage source inverter is a simple scheme that does not need long computation time and can be implanted without mechanical speed sensors and is insensitive to parameter variations. In principle, the motor terminal voltages and currents are sampled and used to estimate the motor flux and torque. Based on estimates of the flux position and the instantaneous errors in torque and stator flux magnitude, a voltage vector is selected to restrict the torque and the flux errors within their respective torque and flux hysteresis bands. In the conventional DTC, the selected voltage vector is applied for the whole switching period regardless of the magnitude of the torque error. This can result in high torque ripple. A better drive performance can be achieved by varying the duty ratio of the selected voltage vector during each switching period according to the magnitude of the torque error and position of the stator flux. A duty ratio control scheme for an inverter-fed induction machine using DTC method is presented in this thesis. The use of the duty ratio control resulted in improved steady state torque response, with less torque ripple than the conventional DTC. Fuzzy logic control was used to implement the duty ratio controller. The effectiveness of the duty ratio method was verified by simulation using MATLAB/SIMULINK®.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Direct torque control(DTC) of an induction motor fed by a voltage source inverter is a simple scheme that does not need long computation time and can be implanted without mechanical speed sensors and is insensitive to parameter variations. In principle, the motor terminal voltages and currents are sampled and used to estimate the motor flux and torque. Based on estimates of the flux position and the instantaneous errors in torque and stator flux magnitude, a voltage vector is selected to restrict the torque and the flux errors within their respective torque and flux hysteresis bands. In the conventional DTC, the selected voltage vector is applied for the whole switching period regardless of the magnitude of the torque error. This can result in high torque ripple. A better drive performance can be achieved by varying the duty ratio of the selected voltage vector during each switching period according to the magnitude of the torque error and position of the stator flux. A duty ratio control scheme for an inverter-fed induction machine using DTC method is presented in this thesis. The use of the duty ratio control resulted in improved steady state torque response, with less torque ripple than the conventional DTC. Fuzzy logic control was used to implement the duty ratio controller. The effectiveness of the duty ratio method was verified by simulation using MATLAB/SIMULINK®.

Key concepts: Direct torque control, Control theory (sociology), Torque ripple, Stall torque, Vector control, Damping torque, Induction motor, Torque

Related papers

Back to paper searchBrowse research topicsOriginal source
Torque ripple reduction in direct torque controlled induction motor drive by using fuzzy controller — Research Paper | ScholarLens