2013NASA Technical Reports Server (NASA)Requires access

Flow Angularity Measurements in the NASA-Langley Transonic Dynamics Tunnel

William T. Yeager, Matthew L. Wilbur, Paul H. Mirick, José A. Rivera

Open publisher page 2 citations

Abstract

An investigation using a survey rake with 11 five-hole pyramid-head probes has been conducted in the Langley Transonic Dynamics Tunnel (TDT) to measure the test section flow angularity. Flow measurements were made in a 10-ft square grid centered about the test section centerline at a single streamwise location for nine Mach numbers ranging from 0.50 to 1.19 at dynamic pressures of 100 and 225 pounds per square foot. Test section flow angularity was found to be minimal with a generally random flow pattern. Corrections for survey rake induced in-plane flow were determined to be necessary; however, corrections for rake induced lift effects were not required.

About this research paper

What this paper is about

An investigation using a survey rake with 11 five-hole pyramid-head probes has been conducted in the Langley Transonic Dynamics Tunnel (TDT) to measure the test section flow angularity. Flow measurements were made in a 10-ft square grid centered about the test section centerline at a single streamwise location for nine Mach numbers ranging from 0.50 to 1.19 at dynamic pressures of 100 and 225 pounds per square foot. Test section flow angularity was found to be minimal with a generally random flow pattern. Corrections for survey rake induced in-plane flow were determined to be necessary; however, corrections for rake induced lift effects were not required.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An investigation using a survey rake with 11 five-hole pyramid-head probes has been conducted in the Langley Transonic Dynamics Tunnel (TDT) to measure the test section flow angularity. Flow measurements were made in a 10-ft square grid centered about the test section centerline at a single streamwise location for nine Mach numbers ranging from 0.50 to 1.19 at dynamic pressures of 100 and 225 pounds per square foot. Test section flow angularity was found to be minimal with a generally random flow pattern. Corrections for survey rake induced in-plane flow were determined to be necessary; however, corrections for rake induced lift effects were not required.

Key concepts: Transonic, Mach number, Rake, Subsonic and transonic wind tunnel, Flow (mathematics), Physics, Mechanics, Structural engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow Angularity Measurements in the NASA-Langley Transonic Dynamics Tunnel — Research Paper | ScholarLens