1975•PubMedRequires access

Comparison of 70 degrees tilt, LBNP, and passive standing as measrues of orthostatic tolerance.

Hyatt Kh, Jacobson Lb, Schneider Vs

Open publisher page 40 citations

Abstract

The present study was performed to assess the reliability of lower body negative pressure (LBNP) as a test of orthostatic tolerance. The need for this assessment arose from the prior observation in this laboratory that some subjects show wide day-to-day variation in heart rate responses to LBNP. The extent of these variations was so great as to a raise a serious question as to the value of LBNP as a measure of study-induced alterations (e.g. those produced by bedrest or weightlessness) in orthostatic tolerance. Five healthy volunteers were subjected to a series of tests, consisting of 70 degrees tilt, LBNP, and passive standing. on three occasions preceding and three occasions following a 2 week period of bedrest. Study results show that it is possible to subdivide the volunteers into subgroups which show either great or little day-to-day variability in any of the three tests. All three tests reaveled bedrest-induced alterations in orthostatic tolerande quite adequately. Of the three tests studied, LBNP most frequently resulted in the largest test-induced heart rate alterations, followed by quiet standing and, finally 70 degrees tilt

About this research paper

What this paper is about

The present study was performed to assess the reliability of lower body negative pressure (LBNP) as a test of orthostatic tolerance. The need for this assessment arose from the prior observation in this laboratory that some subjects show wide day-to-day variation in heart rate responses to LBNP. The extent of these variations was so great as to a raise a serious question as to the value of LBNP as a measure of study-induced alterations (e.g. those produced by bedrest or weightlessness) in orthostatic tolerance. Five healthy volunteers were subjected to a series of tests, consisting of 70 degrees tilt, LBNP, and passive standing. on three occasions preceding and three occasions following a 2 week period of bedrest. Study results show that it is possible to subdivide the volunteers into subgroups which show either great or little day-to-day variability in any of the three tests. All three tests reaveled bedrest-induced alterations in orthostatic tolerande quite adequately. Of the three tests studied, LBNP most frequently resulted in the largest test-induced heart rate alterations, followed by quiet standing and, finally 70 degrees tilt

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The present study was performed to assess the reliability of lower body negative pressure (LBNP) as a test of orthostatic tolerance. The need for this assessment arose from the prior observation in this laboratory that some subjects show wide day-to-day variation in heart rate responses to LBNP. The extent of these variations was so great as to a raise a serious question as to the value of LBNP as a measure of study-induced alterations (e.g. those produced by bedrest or weightlessness) in orthostatic tolerance. Five healthy volunteers were subjected to a series of tests, consisting of 70 degrees tilt, LBNP, and passive standing. on three occasions preceding and three occasions following a 2 week period of bedrest. Study results show that it is possible to subdivide the volunteers into subgroups which show either great or little day-to-day variability in any of the three tests. All three tests reaveled bedrest-induced alterations in orthostatic tolerande quite adequately. Of the three tests studied, LBNP most frequently resulted in the largest test-induced heart rate alterations, followed by quiet standing and, finally 70 degrees tilt

Key concepts: Orthostatic vital signs, Heart rate, Medicine, Tilt (camera), Lower body, Blood pressure, Cardiology, Physical medicine and rehabilitation

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of 70 degrees tilt, LBNP, and passive standing as measrues of orthostatic tolerance. — Research Paper | ScholarLens