1958OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

INSTALLATION OF AN IRRADIATION FACILITY FOR 1 KILOCURIE OF RADIOCOBALT

M. Lefórt, X. Tarrago

Open publisher page 0 citations

Abstract

Design of a kilocurie Co/sup 60/ gamma-ray source is described. Irradiation facilities are given both for research on radiation chemistry and photonuclear reactions. Cobalt samples were placed in six small cylinders in a lead drum. Dose-rates are indicated for various exposure chambers. The volume of the central exposure chamber is of 1,000 cc and the integral dose rate is of 2 x 10/sup 8/ rads kg/hour. Tubes or electrical leads connected to external apparatus can easily be introduced with the sample. (auth)

About this research paper

What this paper is about

Design of a kilocurie Co/sup 60/ gamma-ray source is described. Irradiation facilities are given both for research on radiation chemistry and photonuclear reactions. Cobalt samples were placed in six small cylinders in a lead drum. Dose-rates are indicated for various exposure chambers. The volume of the central exposure chamber is of 1,000 cc and the integral dose rate is of 2 x 10/sup 8/ rads kg/hour. Tubes or electrical leads connected to external apparatus can easily be introduced with the sample. (auth)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Design of a kilocurie Co/sup 60/ gamma-ray source is described. Irradiation facilities are given both for research on radiation chemistry and photonuclear reactions. Cobalt samples were placed in six small cylinders in a lead drum. Dose-rates are indicated for various exposure chambers. The volume of the central exposure chamber is of 1,000 cc and the integral dose rate is of 2 x 10/sup 8/ rads kg/hour. Tubes or electrical leads connected to external apparatus can easily be introduced with the sample. (auth)

Key concepts: Cobalt-60, Radiochemistry, Irradiation, Isotopes of cobalt, Dose rate, Gamma ray, Radiation, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source