Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

M. L. Franklin, W. A. Gordon

Open publisher page 0 citations

Abstract

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

About this research paper

What this paper is about

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Key concepts: Photomultiplier, Dynamic range, Electronic circuit, Repeatability, Photoelectric effect, Wide dynamic range, Range (aeronautics), Spectrometer

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers — Research Paper | ScholarLens