Hepatogastroenterology
Toshio Kurihara, Takao Itoi, Atsushi Sofuni, Fumihide Itokawa, Takayoshi Tsuchiya, Kentaro Ishii, Shujiro Tsuji, Nobuhito Ikeuchi, Fuminori Moriyasu
Abstract
Toshio Kurihara, Takao Itoi, Atsushi Sofuni, Fumihide Itokawa, Takayoshi Tsuchiya, Kentaro Ishii, Shujiro Tsuji, Nobuhito Ikeuchi, Fuminori Moriyasu
Abstract
BACKGROUND/AIMS: ERCP-related procedures involve radiation exposure of patients and medical staff. We developed a novel protective lead shield which is attached around the fluoroscopy generator. Here we examine levels of radiation exposure to patients, endoscopists and assistants, and evaluate the usefulness of the newly designed protective shield. METHODOLOGY: Four-hundred and seventy-one ERCP procedures were performed from April 2006 to April 2007. At first, we compared the radiation dose of consecutive fluoroscopy conditions with pulse fluoroscopy of 15 per second and then the radiation dose with and without the protective shield. Next, we measured the radiation exposure of endoscopists and assistants in the clinical setting monitored by digital dosimeter during ERCP procedure. RESULTS: The radiation dose was the most at the 45° direction. Using pulse fluoroscopy of 15 per second the radiation dose of patients and endoscopists decreased by about half. Using both pulse fluoroscopy of 15 per second and the protective shield, the radiation dose at the endoscopist's position was reduced up to 97%. The total fluoroscopy time was 5851 minutes in the 471 ERCP cases. Using pulse 15 and the protective lead shield, the radiation exposure dose of one endoscopist and two assistants were 2430.8, 2673.9 and 1375.0µSv, respectively. CONCLUSIONS: Novel protective lead shield in combination with pulse fluoroscopy can significantly reduce the radiation exposure leading to avoid unnecessary radiation exposure to patients and medical staff.
OpenAlex reports 556 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND/AIMS: ERCP-related procedures involve radiation exposure of patients and medical staff. We developed a novel protective lead shield which is attached around the fluoroscopy generator. Here we examine levels of radiation exposure to patients, endoscopists and assistants, and evaluate the usefulness of the newly designed protective shield. METHODOLOGY: Four-hundred and seventy-one ERCP procedures were performed from April 2006 to April 2007. At first, we compared the radiation dose of consecutive fluoroscopy conditions with pulse fluoroscopy of 15 per second and then the radiation dose with and without the protective shield. Next, we measured the radiation exposure of endoscopists and assistants in the clinical setting monitored by digital dosimeter during ERCP procedure. RESULTS: The radiation dose was the most at the 45° direction. Using pulse fluoroscopy of 15 per second the radiation dose of patients and endoscopists decreased by about half. Using both pulse fluoroscopy of 15 per second and the protective shield, the radiation dose at the endoscopist's position was reduced up to 97%. The total fluoroscopy time was 5851 minutes in the 471 ERCP cases. Using pulse 15 and the protective lead shield, the radiation exposure dose of one endoscopist and two assistants were 2430.8, 2673.9 and 1375.0µSv, respectively. CONCLUSIONS: Novel protective lead shield in combination with pulse fluoroscopy can significantly reduce the radiation exposure leading to avoid unnecessary radiation exposure to patients and medical staff.
Key concepts: Fluoroscopy, Dosimeter, Medicine, Radiation exposure, Lead apron, Nuclear medicine, Radiation protection, Radiation dose