Determination of trace amounts of nickel(II) with α-(2-Benzimidazolyl)-α',α''-(N-5-nitro-2-pyridyl hydrazone) toluene in the presence of triton X-100 by fluorescence method
Chan Il Park, Hyeon Su Kim, Gi Won
Abstract
Chan Il Park, Hyeon Su Kim, Gi Won
Abstract
A method is described for the fluorimetric determination of nickel, based on the formation of , -(N-5-Nitro-2-Pyridylhydrazone)-toluene complex in the presence of a non-ionic surfactant. The complex has practically no fluorescence in the absence of surfactant, but the addition of Triton X-100 makes possible the fluorimetric determination of low concentrations of Ni(II) as it enhances the fluorescenceintensity of the complex by up to about 5-fold. This method is very sensitive and selectrive for the direct determination of nickel ion. The optimum conditions are a Triton X-100 concentration of 2.0 mL(5.0%, v/v) and pH chloride-ammonia buffer). The fluorescence is measured at 337 nm of emission wavelength under 300 nm of excitation wavelength. The fluorescence intensity is a linear function of the concentration of Ni(II) in the range 5-70 ng/mL, and the detection limit is 2.0 nm/mL. The proposed method has been successfully applied to the determination of trace amounts of Ni(II) in food and human hair samples.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method is described for the fluorimetric determination of nickel, based on the formation of , -(N-5-Nitro-2-Pyridylhydrazone)-toluene complex in the presence of a non-ionic surfactant. The complex has practically no fluorescence in the absence of surfactant, but the addition of Triton X-100 makes possible the fluorimetric determination of low concentrations of Ni(II) as it enhances the fluorescenceintensity of the complex by up to about 5-fold. This method is very sensitive and selectrive for the direct determination of nickel ion. The optimum conditions are a Triton X-100 concentration of 2.0 mL(5.0%, v/v) and pH chloride-ammonia buffer). The fluorescence is measured at 337 nm of emission wavelength under 300 nm of excitation wavelength. The fluorescence intensity is a linear function of the concentration of Ni(II) in the range 5-70 ng/mL, and the detection limit is 2.0 nm/mL. The proposed method has been successfully applied to the determination of trace amounts of Ni(II) in food and human hair samples.
Key concepts: Chemistry, Toluene, Hydrazone, Detection limit, Fluorescence, Nickel, Pulmonary surfactant, Triton X-100