2012Anaesthesia and Intensive CareOpen access

The Self-Pressurising Air-Q® Intubating Laryngeal Airway for Airway Maintenance during Anaesthesia in Adults: A Report of the First 100 Uses

Richard E. Galgon, Kristopher M. Schroeder, Aaron M. Joffe

Open full text 12 citations

Abstract

The self-pressurising air-Q® Intubating Laryngeal Airway is a new, commercially available, supraglottic airway device that incorporates a self-regulating periglottic cuff. In this retrospective review, we describe our initial clinical experience using the device in 100 patients. The ease and number of insertion attempts, airway seal pressure, device positioning, intubation success and oropharyngeal morbidity were recorded. The air-Q Intubating Laryngeal Airway was successfully inserted in all 100 patients and functioned adequately as a primary airway in 70 of the 72 patients in which it was used for this purpose. The median (interquartile range [range]) airway seal pressure was 22 (19-29, [10-40]) cmH2O. Intubation via the air-Q Intubating Laryngeal Airway was successful in 28 of 29 (97%) patients. Eleven percent of patients complained of sore throat postoperatively before discharge. In our series, the air-Q Intubating Laryngeal Airway performed adequately as a primary airway during anaesthesia with respect to ease of insertion, adequacy of airway maintenance and as a conduit for intubation in both anticipated and unanticipated difficult airways. Although our initial experience is positive, further investigation with larger numbers of observations are needed as the upper limits of the 95% confidence intervals for device failure (the worst failure rate the clinician could expect) are still high.

Open-access reader

About this research paper

What this paper is about

The self-pressurising air-Q® Intubating Laryngeal Airway is a new, commercially available, supraglottic airway device that incorporates a self-regulating periglottic cuff. In this retrospective review, we describe our initial clinical experience using the device in 100 patients. The ease and number of insertion attempts, airway seal pressure, device positioning, intubation success and oropharyngeal morbidity were recorded. The air-Q Intubating Laryngeal Airway was successfully inserted in all 100 patients and functioned adequately as a primary airway in 70 of the 72 patients in which it was used for this purpose. The median (interquartile range [range]) airway seal pressure was 22 (19-29, [10-40]) cmH2O. Intubation via the air-Q Intubating Laryngeal Airway was successful in 28 of 29 (97%) patients. Eleven percent of patients complained of sore throat postoperatively before discharge. In our series, the air-Q Intubating Laryngeal Airway performed adequately as a primary airway during anaesthesia with respect to ease of insertion, adequacy of airway maintenance and as a conduit for intubation in both anticipated and unanticipated difficult airways. Although our initial experience is positive, further investigation with larger numbers of observations are needed as the upper limits of the 95% confidence intervals for device failure (the worst failure rate the clinician could expect) are still high.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The self-pressurising air-Q® Intubating Laryngeal Airway is a new, commercially available, supraglottic airway device that incorporates a self-regulating periglottic cuff. In this retrospective review, we describe our initial clinical experience using the device in 100 patients. The ease and number of insertion attempts, airway seal pressure, device positioning, intubation success and oropharyngeal morbidity were recorded. The air-Q Intubating Laryngeal Airway was successfully inserted in all 100 patients and functioned adequately as a primary airway in 70 of the 72 patients in which it was used for this purpose. The median (interquartile range [range]) airway seal pressure was 22 (19-29, [10-40]) cmH2O. Intubation via the air-Q Intubating Laryngeal Airway was successful in 28 of 29 (97%) patients. Eleven percent of patients complained of sore throat postoperatively before discharge. In our series, the air-Q Intubating Laryngeal Airway performed adequately as a primary airway during anaesthesia with respect to ease of insertion, adequacy of airway maintenance and as a conduit for intubation in both anticipated and unanticipated difficult airways. Although our initial experience is positive, further investigation with larger numbers of observations are needed as the upper limits of the 95% confidence intervals for device failure (the worst failure rate the clinician could expect) are still high.

Key concepts: Medicine, Airway, Sore throat, Anesthesia, Intubation, Cuff, Supraglottic airway, Interquartile range

Related papers

Back to paper searchBrowse research topicsOriginal source
The Self-Pressurising Air-Q® Intubating Laryngeal Airway for Airway Maintenance during Anaesthesia in Adults: A Report of the First 100 Uses — Research Paper | ScholarLens