2008•PubMedRequires access

Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty.

Cesar A. Atienza, William James Maloney

Open publisher page 24 citations

Abstract

Polyethylene wear-induced osteolysis is the most significant primary factor limiting the life span of total joint arthroplasty. To reduce ultra-high-molecular-weight polyethylene (UHMWPE) particulate wear debris, highly cross-linked polyethylene (HXPE) bearings have been introduced in total hip arthroplasty (THA). In vitro hip simulator wear studies with HXPE have demonstrated a decrease in volumetric wear at the hip by 42% to 100% when compared with conventional metal-on-polyethylene bearings. Early to intermediate clinical results suggest that the in vivo wear properties of HXPE products are superior to those of conventional UHMWPE. Second-generation HXPE materials that utilize alternate cross-linking and free radical quenching techniques have been developed and propose to further minimize wear and oxidation.

About this research paper

What this paper is about

Polyethylene wear-induced osteolysis is the most significant primary factor limiting the life span of total joint arthroplasty. To reduce ultra-high-molecular-weight polyethylene (UHMWPE) particulate wear debris, highly cross-linked polyethylene (HXPE) bearings have been introduced in total hip arthroplasty (THA). In vitro hip simulator wear studies with HXPE have demonstrated a decrease in volumetric wear at the hip by 42% to 100% when compared with conventional metal-on-polyethylene bearings. Early to intermediate clinical results suggest that the in vivo wear properties of HXPE products are superior to those of conventional UHMWPE. Second-generation HXPE materials that utilize alternate cross-linking and free radical quenching techniques have been developed and propose to further minimize wear and oxidation.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Polyethylene wear-induced osteolysis is the most significant primary factor limiting the life span of total joint arthroplasty. To reduce ultra-high-molecular-weight polyethylene (UHMWPE) particulate wear debris, highly cross-linked polyethylene (HXPE) bearings have been introduced in total hip arthroplasty (THA). In vitro hip simulator wear studies with HXPE have demonstrated a decrease in volumetric wear at the hip by 42% to 100% when compared with conventional metal-on-polyethylene bearings. Early to intermediate clinical results suggest that the in vivo wear properties of HXPE products are superior to those of conventional UHMWPE. Second-generation HXPE materials that utilize alternate cross-linking and free radical quenching techniques have been developed and propose to further minimize wear and oxidation.

Key concepts: Polyethylene, Cross-linked polyethylene, Total hip arthroplasty, Medicine, Limiting, Bearing (navigation), Osteolysis, Joint arthroplasty

Related papers

Back to paper searchBrowse research topicsOriginal source
Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty. — Research Paper | ScholarLens