1986OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

Rejecting diffractometer with linear coordinate detector for single crystals

O.I. Ageev, L.P. Glazova, D.A. Goganov, B.V. Kazanskii, B.M. Reizis

Open publisher page 0 citations

Abstract

Use of an x-ray beam that is convergent in the specimen and a recording system based on a linear coordinate detector has led to the creation of the ADR-3--a new type of goniometer-free rejecting diffractometer. The deviation of this orientation angle of the surface of a cut from a specified angle is determined by electronic data processing entirely without mechanical movement. The rejector can check the quality of cut treatment and allows the block distribution over the surface of a single crystal to be studied with a localization of 0.2 mm. The test results of the goniometer-free rejecting diffractometer showed its ability to check cut angles under industrial conditions.

About this research paper

What this paper is about

Use of an x-ray beam that is convergent in the specimen and a recording system based on a linear coordinate detector has led to the creation of the ADR-3--a new type of goniometer-free rejecting diffractometer. The deviation of this orientation angle of the surface of a cut from a specified angle is determined by electronic data processing entirely without mechanical movement. The rejector can check the quality of cut treatment and allows the block distribution over the surface of a single crystal to be studied with a localization of 0.2 mm. The test results of the goniometer-free rejecting diffractometer showed its ability to check cut angles under industrial conditions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Use of an x-ray beam that is convergent in the specimen and a recording system based on a linear coordinate detector has led to the creation of the ADR-3--a new type of goniometer-free rejecting diffractometer. The deviation of this orientation angle of the surface of a cut from a specified angle is determined by electronic data processing entirely without mechanical movement. The rejector can check the quality of cut treatment and allows the block distribution over the surface of a single crystal to be studied with a localization of 0.2 mm. The test results of the goniometer-free rejecting diffractometer showed its ability to check cut angles under industrial conditions.

Key concepts: Goniometer, Diffractometer, Optics, Orientation (vector space), Detector, Surface (topology), Materials science, Block (permutation group theory)

Related papers

Back to paper searchBrowse research topicsOriginal source
Rejecting diffractometer with linear coordinate detector for single crystals — Research Paper | ScholarLens