Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital
Joan-Lluis Vives-Corrons, I Besson, Josep M. Jou, Gabriela Gutiérrez
Abstract
Joan-Lluis Vives-Corrons, I Besson, Josep M. Jou, Gabriela Gutiérrez
Abstract
The Abbott (R) Cell-Dyn 3500 (Abbott CD 3500, Abbott Diagnostics Division, Mountain View, CA) is a fully automated hematology analyzer capable of providing a complete blood count (CBC) profile, including a five-part differential leukocyte count (DLC) and flagging system in this study. The CBC profile and DLC flagging system of the Abbott CD 3500 were evaluated according to the HA-20 protocol of the National Committee for Clinical and Laboratory Standards (NCCLS) and compared to the Technicon H*2 blood analyzer currently used in the authors' laboratory. Linearity, carryover, precision, and stability were all within the limits established by the manufacturer. No significant break-downs were found during the evaluation period. Evaluation of DLC indicated an excellent correlation with the manual reference method for neutrophils, lymphocytes, and eosinophils (r = 0.916, 0.936, 0.967, respectively), a good correlation for monocytes (r = 0.811) and a poor correlation for basophils (r = 0.224). Overall flagging for morphologic abnormalities displayed higher sensitivity (85%) than specificity (67%), with a false-positive ratio of 33%. In general, these results are in accordance with those obtained by other authors in the same period of time.
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The Abbott (R) Cell-Dyn 3500 (Abbott CD 3500, Abbott Diagnostics Division, Mountain View, CA) is a fully automated hematology analyzer capable of providing a complete blood count (CBC) profile, including a five-part differential leukocyte count (DLC) and flagging system in this study. The CBC profile and DLC flagging system of the Abbott CD 3500 were evaluated according to the HA-20 protocol of the National Committee for Clinical and Laboratory Standards (NCCLS) and compared to the Technicon H*2 blood analyzer currently used in the authors' laboratory. Linearity, carryover, precision, and stability were all within the limits established by the manufacturer. No significant break-downs were found during the evaluation period. Evaluation of DLC indicated an excellent correlation with the manual reference method for neutrophils, lymphocytes, and eosinophils (r = 0.916, 0.936, 0.967, respectively), a good correlation for monocytes (r = 0.811) and a poor correlation for basophils (r = 0.224). Overall flagging for morphologic abnormalities displayed higher sensitivity (85%) than specificity (67%), with a false-positive ratio of 33%. In general, these results are in accordance with those obtained by other authors in the same period of time.
Key concepts: Hematology analyzer, Flagging, AutoAnalyzer, Medicine, Leukocyte Counts, Blood film, Eosinopenia, Hematology