1999PubMedRequires access

[Changes of arterial blood pressure and heart rate during induction of anesthesia with propofol--efficacy of propofol titration using bispectral index as an indicator].

Takako Masuda, Y Jinnouchi, Hiroyuki Kitahata, Haruka Kimura, S Oshita

Open publisher page 6 citations

Abstract

Bispectral index (BIS) is a processed EEG parameter that measures the hypnotic effects of anesthetic and sedative agents on the brain. We studied whether propofol titration using BIS allows us to prevent hemodynamic changes during induction of anesthesia and endotracheal intubation. Thirty patients without hypertension and obesity were studied. In the titration group (n = 15), BIS was maintained at 40 during induction of anesthesia with propofol. In the bolus group, anesthesia was induced with a bolus infusion of propofol 2 mg.kg-1 (n = 15). Arterial blood pressure and heart rate were recorded before induction of anesthesia, during induction of anesthesia, immediately after, and 1 min, 2 min, and 3 min after intubation. Diastolic blood pressure and heart rate increased significantly after endotracheal intubation in both groups. Systolic blood pressure significantly increased immediately after intubation in the bolus group, but was unchanged in the titration group. These results suggest that BIS is useful to prevent significant increases in systolic blood pressure associated with endotracheal intubation during induction of anesthesia with propofol.

About this research paper

What this paper is about

Bispectral index (BIS) is a processed EEG parameter that measures the hypnotic effects of anesthetic and sedative agents on the brain. We studied whether propofol titration using BIS allows us to prevent hemodynamic changes during induction of anesthesia and endotracheal intubation. Thirty patients without hypertension and obesity were studied. In the titration group (n = 15), BIS was maintained at 40 during induction of anesthesia with propofol. In the bolus group, anesthesia was induced with a bolus infusion of propofol 2 mg.kg-1 (n = 15). Arterial blood pressure and heart rate were recorded before induction of anesthesia, during induction of anesthesia, immediately after, and 1 min, 2 min, and 3 min after intubation. Diastolic blood pressure and heart rate increased significantly after endotracheal intubation in both groups. Systolic blood pressure significantly increased immediately after intubation in the bolus group, but was unchanged in the titration group. These results suggest that BIS is useful to prevent significant increases in systolic blood pressure associated with endotracheal intubation during induction of anesthesia with propofol.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Bispectral index (BIS) is a processed EEG parameter that measures the hypnotic effects of anesthetic and sedative agents on the brain. We studied whether propofol titration using BIS allows us to prevent hemodynamic changes during induction of anesthesia and endotracheal intubation. Thirty patients without hypertension and obesity were studied. In the titration group (n = 15), BIS was maintained at 40 during induction of anesthesia with propofol. In the bolus group, anesthesia was induced with a bolus infusion of propofol 2 mg.kg-1 (n = 15). Arterial blood pressure and heart rate were recorded before induction of anesthesia, during induction of anesthesia, immediately after, and 1 min, 2 min, and 3 min after intubation. Diastolic blood pressure and heart rate increased significantly after endotracheal intubation in both groups. Systolic blood pressure significantly increased immediately after intubation in the bolus group, but was unchanged in the titration group. These results suggest that BIS is useful to prevent significant increases in systolic blood pressure associated with endotracheal intubation during induction of anesthesia with propofol.

Key concepts: Propofol, Bispectral index, Anesthesia, Medicine, Blood pressure, Heart rate, Intubation, Bolus (digestion)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Changes of arterial blood pressure and heart rate during induction of anesthesia with propofol--efficacy of propofol titration using bispectral index as an indicator]. — Research Paper | ScholarLens