1963OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

DETECTION OF TWO PARTICLES IN SPARK CHAMBER

А. И. Бабаев, V. Kaftanov

Open publisher page 0 citations

Abstract

The efficiency of a six-layer cylindrical spark chamber for detection of two particles in the decay mu yields e + gamma and mu yields 3 e was investigated. The outside diameter of the chamber is 203 mm and its electrodes were constructed of duraluminum with a gap of 7 mm. The chamber was filled with neon at a pressure of 1.1 atm. An exponential pulse with an amplitude of 11 kv was supplied to the electrodes. The efficiency of the chamber is dependent on the delay time of the voltage impulse. (C.E.S.)

About this research paper

What this paper is about

The efficiency of a six-layer cylindrical spark chamber for detection of two particles in the decay mu yields e + gamma and mu yields 3 e was investigated. The outside diameter of the chamber is 203 mm and its electrodes were constructed of duraluminum with a gap of 7 mm. The chamber was filled with neon at a pressure of 1.1 atm. An exponential pulse with an amplitude of 11 kv was supplied to the electrodes. The efficiency of the chamber is dependent on the delay time of the voltage impulse. (C.E.S.)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The efficiency of a six-layer cylindrical spark chamber for detection of two particles in the decay mu yields e + gamma and mu yields 3 e was investigated. The outside diameter of the chamber is 203 mm and its electrodes were constructed of duraluminum with a gap of 7 mm. The chamber was filled with neon at a pressure of 1.1 atm. An exponential pulse with an amplitude of 11 kv was supplied to the electrodes. The efficiency of the chamber is dependent on the delay time of the voltage impulse. (C.E.S.)

Key concepts: Spark chamber, Impulse (physics), Materials science, Electrode, Voltage, Spark gap, SPARK (programming language), Atomic physics

Related papers

Back to paper searchBrowse research topicsOriginal source
DETECTION OF TWO PARTICLES IN SPARK CHAMBER — Research Paper | ScholarLens