2000PubMedRequires access

Aortic valve replacement with concomitant annular enlargement for small aortic annulus of less than 19 mm.

Hiromitsu Takakura, T Sasaki, Kouichi Hashimoto, TAKASHI HACHIYA, Katsuhisa Onoguchi, Motohiro Oshiumi, Shoko Takeuchi

Open publisher page 0 citations

Abstract

Three female patients with aortic stenosis associated with a severely small annulus underwent aortic valve replacement. In intraoperative measurements, a 19-mm obtulator could not pass through the aortic annulus in each case. We therefore concluded that it would be difficult to implant an appropriate-sized prosthesis in a routine fashion, so we performed an annular enlargement in a modified Nicks procedure. By using a wide teardrop-shaped patch for enlargement and slightly tilting insertion of a prosthesis, a 21 mm bileaflet mechanical prosthesis could be inserted into the enlarged annulus. Despite being a simpler method than other enlarging procedures, a two- or three-sizes larger prosthesis than the native annulus can be inserted with relative ease. Thus, the use of a 19 mm mechanical prosthesis may be avoidable in most adult cases.

About this research paper

What this paper is about

Three female patients with aortic stenosis associated with a severely small annulus underwent aortic valve replacement. In intraoperative measurements, a 19-mm obtulator could not pass through the aortic annulus in each case. We therefore concluded that it would be difficult to implant an appropriate-sized prosthesis in a routine fashion, so we performed an annular enlargement in a modified Nicks procedure. By using a wide teardrop-shaped patch for enlargement and slightly tilting insertion of a prosthesis, a 21 mm bileaflet mechanical prosthesis could be inserted into the enlarged annulus. Despite being a simpler method than other enlarging procedures, a two- or three-sizes larger prosthesis than the native annulus can be inserted with relative ease. Thus, the use of a 19 mm mechanical prosthesis may be avoidable in most adult cases.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three female patients with aortic stenosis associated with a severely small annulus underwent aortic valve replacement. In intraoperative measurements, a 19-mm obtulator could not pass through the aortic annulus in each case. We therefore concluded that it would be difficult to implant an appropriate-sized prosthesis in a routine fashion, so we performed an annular enlargement in a modified Nicks procedure. By using a wide teardrop-shaped patch for enlargement and slightly tilting insertion of a prosthesis, a 21 mm bileaflet mechanical prosthesis could be inserted into the enlarged annulus. Despite being a simpler method than other enlarging procedures, a two- or three-sizes larger prosthesis than the native annulus can be inserted with relative ease. Thus, the use of a 19 mm mechanical prosthesis may be avoidable in most adult cases.

Key concepts: Cardiac skeleton, Annulus (botany), Medicine, Prosthesis, Aortic valve replacement, Stenosis, Concomitant, Aortic valve

Related papers

Back to paper searchBrowse research topicsOriginal source
Aortic valve replacement with concomitant annular enlargement for small aortic annulus of less than 19 mm. — Research Paper | ScholarLens