2011Unpublished venueRequires access

Methane concentration measurement using tunable diode laser in near infrared spectrum

Javad Shemshad, Saiied Mostafa Aminossadati, Mehmet Siddik Kizil

Open publisher page 0 citations

Abstract

The main element for a successful laser-based gas sensing system significantly relies on the availability and performance of tunable laser sources in the measurement spectra. In addition, an appropriate detection scheme should be adopted to obtain a sensitive measurement. Wavelength modulation spectroscopy (WMS) is considered as a sensitive measuring technique in a gas monitoring applications. The paper investigates the experimental results of laser-based methane detection system using WMS technique. Methane absorption lines in near infrared spectrum are targeted using tunable distributed feedback laser (DFB) by modulating the laser current over the absorption lines. Methane concentrations in the range from 0.1% to %5 volume concentration in mixtures with nitrogen as a background gas have been successfully measured.

About this research paper

What this paper is about

The main element for a successful laser-based gas sensing system significantly relies on the availability and performance of tunable laser sources in the measurement spectra. In addition, an appropriate detection scheme should be adopted to obtain a sensitive measurement. Wavelength modulation spectroscopy (WMS) is considered as a sensitive measuring technique in a gas monitoring applications. The paper investigates the experimental results of laser-based methane detection system using WMS technique. Methane absorption lines in near infrared spectrum are targeted using tunable distributed feedback laser (DFB) by modulating the laser current over the absorption lines. Methane concentrations in the range from 0.1% to %5 volume concentration in mixtures with nitrogen as a background gas have been successfully measured.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The main element for a successful laser-based gas sensing system significantly relies on the availability and performance of tunable laser sources in the measurement spectra. In addition, an appropriate detection scheme should be adopted to obtain a sensitive measurement. Wavelength modulation spectroscopy (WMS) is considered as a sensitive measuring technique in a gas monitoring applications. The paper investigates the experimental results of laser-based methane detection system using WMS technique. Methane absorption lines in near infrared spectrum are targeted using tunable distributed feedback laser (DFB) by modulating the laser current over the absorption lines. Methane concentrations in the range from 0.1% to %5 volume concentration in mixtures with nitrogen as a background gas have been successfully measured.

Key concepts: Tunable diode laser absorption spectroscopy, Methane, Laser, Distributed feedback laser, Tunable laser, Absorption spectroscopy, Materials science, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Methane concentration measurement using tunable diode laser in near infrared spectrum — Research Paper | ScholarLens