CT virtual endoscopy of the auditory ossicular chain: clinical applications.
D Wang, Wentao Zhang, Min Xiong, Ma Yu, Jing Xu
Abstract
D Wang, Wentao Zhang, Min Xiong, Ma Yu, Jing Xu
Abstract
OBJECTIVE: To evaluate the clinical applications and limitations of CT virtual endoscopy (CTVE) in the auditory ossicular chain. METHODS: CTVE of the auditory ossicular chain was performed with 1.0 mm collimation at pitch 1.0, bone algorithm, 9.6 cm field of view, and 0.1-0.2 mm reconstruction interval in 40 patients with middle ear diseases. 30 cases were confirmed by surgery. Results were compared with the findings of axial high resolution CT (HRCT) and multiplanar reformation (MPR) images and surgery. RESULTS: The accuracy of CTVE images in detecting ossicular destruction was 92.6%, significantly higher than that of axial HRCT (83.9%) and multiplanar reformation (76.5%) images. CTVE could also clearly reveal the postoperative condition and congenital dysplasia of the auditory ossicular chain. CONCLUSIONS: CTVE can clearly demonstrate a three-dimensional image of the auditory ossicular chain and is useful in evaluating diseases of the ear, especially the auditory ossicles. CTVE could not clearly demonstrate abnormal soft tissue within the tympanic cavity, abnormal changes of the tympanic membrane and tympanic walls, and could be easily influenced by artificial factors.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate the clinical applications and limitations of CT virtual endoscopy (CTVE) in the auditory ossicular chain. METHODS: CTVE of the auditory ossicular chain was performed with 1.0 mm collimation at pitch 1.0, bone algorithm, 9.6 cm field of view, and 0.1-0.2 mm reconstruction interval in 40 patients with middle ear diseases. 30 cases were confirmed by surgery. Results were compared with the findings of axial high resolution CT (HRCT) and multiplanar reformation (MPR) images and surgery. RESULTS: The accuracy of CTVE images in detecting ossicular destruction was 92.6%, significantly higher than that of axial HRCT (83.9%) and multiplanar reformation (76.5%) images. CTVE could also clearly reveal the postoperative condition and congenital dysplasia of the auditory ossicular chain. CONCLUSIONS: CTVE can clearly demonstrate a three-dimensional image of the auditory ossicular chain and is useful in evaluating diseases of the ear, especially the auditory ossicles. CTVE could not clearly demonstrate abnormal soft tissue within the tympanic cavity, abnormal changes of the tympanic membrane and tympanic walls, and could be easily influenced by artificial factors.
Key concepts: Middle ear, Medicine, Ossicles, Tympanic cavity, Tympanoplasty, Temporal bone, Endoscopy, Radiology