1991Unpublished venueRequires access

DISCOMFORT GLARE FROM D1 HEADLAMPS OF DIFFERENT SIZE

Jwam Alferdinck, J. Varkevisser

Open publisher page 11 citations

Abstract

In the frame of the European research project VEDILIS (VEhicle DIscharge LIghting System) the influence of the size of D1 headlamps on the discomfort glare was examined in the laboratory. The discomfort was subjectively assessed with the nine-point rating scale of De Boer. The glare sources were rectangular with areas ranging from 0.00059 to 0.151 square degrees. The glare angles varied from 1.72 to 6.84 degrees. The glare illuminance at the observer's eye, varied from 0.03 to 3 lux. In addition to the expected effects of the glare illuminance and the glare angle on the discomfort rating, a small but significant effect of the size of the glare source was found. A glare source which is a factor two smaller in size (factor four in area) increases the discomfort glare with 0.1 points. This increase can be compensated by a decrease of the light intensity of the lamp by 11%. No effect of age and sex on the discomfort glare was found. However, a correlation between age and disability glare was found. (A)

About this research paper

What this paper is about

In the frame of the European research project VEDILIS (VEhicle DIscharge LIghting System) the influence of the size of D1 headlamps on the discomfort glare was examined in the laboratory. The discomfort was subjectively assessed with the nine-point rating scale of De Boer. The glare sources were rectangular with areas ranging from 0.00059 to 0.151 square degrees. The glare angles varied from 1.72 to 6.84 degrees. The glare illuminance at the observer's eye, varied from 0.03 to 3 lux. In addition to the expected effects of the glare illuminance and the glare angle on the discomfort rating, a small but significant effect of the size of the glare source was found. A glare source which is a factor two smaller in size (factor four in area) increases the discomfort glare with 0.1 points. This increase can be compensated by a decrease of the light intensity of the lamp by 11%. No effect of age and sex on the discomfort glare was found. However, a correlation between age and disability glare was found. (A)

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the frame of the European research project VEDILIS (VEhicle DIscharge LIghting System) the influence of the size of D1 headlamps on the discomfort glare was examined in the laboratory. The discomfort was subjectively assessed with the nine-point rating scale of De Boer. The glare sources were rectangular with areas ranging from 0.00059 to 0.151 square degrees. The glare angles varied from 1.72 to 6.84 degrees. The glare illuminance at the observer's eye, varied from 0.03 to 3 lux. In addition to the expected effects of the glare illuminance and the glare angle on the discomfort rating, a small but significant effect of the size of the glare source was found. A glare source which is a factor two smaller in size (factor four in area) increases the discomfort glare with 0.1 points. This increase can be compensated by a decrease of the light intensity of the lamp by 11%. No effect of age and sex on the discomfort glare was found. However, a correlation between age and disability glare was found. (A)

Key concepts: GLARE, Illuminance, Optometry, Optics, Medicine, Materials science, Physics, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
DISCOMFORT GLARE FROM D1 HEADLAMPS OF DIFFERENT SIZE — Research Paper | ScholarLens