Miscibility of lubricants with refrigerants. Final report

M.B. Pate, S.C. Zoz, L.J. Berkenbosch

Open publisher page 0 citations

Abstract

Miscibility data have been obtained for a variety of non-CFC refrigerants and their potential lubricants. Ten different refrigerants and fourteen (14) lubricants were investigated. Experiments were performed in two phases: Phase 1 focused on performing screening tests for miscibility using refrigerant concentrations of 10, 50 and 95% and Phase 2 consisted of obtained further refrigerant concentrations of 20, 35, 65, 80, and 90%. The complete data set is presented herein. The miscibility tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The bath temperature can be precisely controlled over a temperature range of {minus}50 C to 90 C ({minus}58 F to 194 F). The test cells are constructed to allow for complete visibility of lubricant-refrigerant mixtures under all test conditions. Each of the refrigerants tested are miscible with at least one of the lubricants, with the exception of R-143a, which exhibits partial miscibility with each of the lubricants.

About this research paper

What this paper is about

Miscibility data have been obtained for a variety of non-CFC refrigerants and their potential lubricants. Ten different refrigerants and fourteen (14) lubricants were investigated. Experiments were performed in two phases: Phase 1 focused on performing screening tests for miscibility using refrigerant concentrations of 10, 50 and 95% and Phase 2 consisted of obtained further refrigerant concentrations of 20, 35, 65, 80, and 90%. The complete data set is presented herein. The miscibility tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The bath temperature can be precisely controlled over a temperature range of {minus}50 C to 90 C ({minus}58 F to 194 F). The test cells are constructed to allow for complete visibility of lubricant-refrigerant mixtures under all test conditions. Each of the refrigerants tested are miscible with at least one of the lubricants, with the exception of R-143a, which exhibits partial miscibility with each of the lubricants.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Miscibility data have been obtained for a variety of non-CFC refrigerants and their potential lubricants. Ten different refrigerants and fourteen (14) lubricants were investigated. Experiments were performed in two phases: Phase 1 focused on performing screening tests for miscibility using refrigerant concentrations of 10, 50 and 95% and Phase 2 consisted of obtained further refrigerant concentrations of 20, 35, 65, 80, and 90%. The complete data set is presented herein. The miscibility tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The bath temperature can be precisely controlled over a temperature range of {minus}50 C to 90 C ({minus}58 F to 194 F). The test cells are constructed to allow for complete visibility of lubricant-refrigerant mixtures under all test conditions. Each of the refrigerants tested are miscible with at least one of the lubricants, with the exception of R-143a, which exhibits partial miscibility with each of the lubricants.

Key concepts: Refrigerant, Miscibility, Lubricant, Thermodynamics, Materials science, Phase (matter), Chemistry, Organic chemistry