STUDIES ON ANALYTICAL METHODS FOR TRACE ELEMENTS IN METALS BY USING RADIOACTIVE ISOTOPE. III. DETERMINATION OF TANTALUM BY MEANS OF ISOTOPE DILUTION METHOD

Hiroshi Amano

Open full text 0 citations

Abstract

The determination of tantalum by isotope dilution method in the presence of niobium was investigated by the use of radioactive isotope tantalum-185. Tantalum was separated from niobium as tantalum-tannin precipitate under the optimum condition of pH 1.9~2.5 and tantalum/niobium ratio up to 1/50. If niobium had been present 100 times or more of tantalum, reprecipitation would have been needed. The reciprocal of the specific activity of tantalum pentoxide preciptiate was in a linear relation to the change in the amount of tantalum added. The recommended method gave an accurate result in the determination of tantalum in steel.

About this research paper

What this paper is about

The determination of tantalum by isotope dilution method in the presence of niobium was investigated by the use of radioactive isotope tantalum-185. Tantalum was separated from niobium as tantalum-tannin precipitate under the optimum condition of pH 1.9~2.5 and tantalum/niobium ratio up to 1/50. If niobium had been present 100 times or more of tantalum, reprecipitation would have been needed. The reciprocal of the specific activity of tantalum pentoxide preciptiate was in a linear relation to the change in the amount of tantalum added. The recommended method gave an accurate result in the determination of tantalum in steel.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The determination of tantalum by isotope dilution method in the presence of niobium was investigated by the use of radioactive isotope tantalum-185. Tantalum was separated from niobium as tantalum-tannin precipitate under the optimum condition of pH 1.9~2.5 and tantalum/niobium ratio up to 1/50. If niobium had been present 100 times or more of tantalum, reprecipitation would have been needed. The reciprocal of the specific activity of tantalum pentoxide preciptiate was in a linear relation to the change in the amount of tantalum added. The recommended method gave an accurate result in the determination of tantalum in steel.

Key concepts: Tantalum, Niobium, Tantalum pentoxide, Vanadium, Isotope dilution, Radiochemistry, Materials science, Niobium pentoxide

Related papers

Back to paper searchBrowse research topicsOriginal source
STUDIES ON ANALYTICAL METHODS FOR TRACE ELEMENTS IN METALS BY USING RADIOACTIVE ISOTOPE. III. DETERMINATION OF TANTALUM BY MEANS OF ISOTOPE DILUTION METHOD — Research Paper | ScholarLens