2000PubMedOpen access

Evaluation of the BioRID P3 and the Hybrid III in pendulum impacts to the back--a comparison to human subject test data.

Astrid Linder, Ulf Bergman, Mats Y. Svensson, David C. Viano

Open full text 5 citations

Abstract

The BioRID P3 (Biofidelic Rear Impact Dummy) and the Hybrid III were evaluated in pendulum impacts to the back and compared to data from previous cadaver tests. The test setup impacting seated cadavers was reproduced with a pendulum impacting seated dummies at the level of T6 (6th thoracic vertebra). The pendulum mass was 23 kg and the impact velocity 4.6 m/s. The results showed that the BioRID P3 was more biofidelic than the Hybrid III in terms of the peak responses and the temporal window of the head and head relative to T1 horizontal, vertical, and angular displacement. This study is an evaluation of both the BioRID P3 and the Hybrid III against a recently available set of human subject data. The study meets the need for validation of the BioRID P3 at a higher impact severity than has been previously accomplished.

About this research paper

What this paper is about

The BioRID P3 (Biofidelic Rear Impact Dummy) and the Hybrid III were evaluated in pendulum impacts to the back and compared to data from previous cadaver tests. The test setup impacting seated cadavers was reproduced with a pendulum impacting seated dummies at the level of T6 (6th thoracic vertebra). The pendulum mass was 23 kg and the impact velocity 4.6 m/s. The results showed that the BioRID P3 was more biofidelic than the Hybrid III in terms of the peak responses and the temporal window of the head and head relative to T1 horizontal, vertical, and angular displacement. This study is an evaluation of both the BioRID P3 and the Hybrid III against a recently available set of human subject data. The study meets the need for validation of the BioRID P3 at a higher impact severity than has been previously accomplished.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The BioRID P3 (Biofidelic Rear Impact Dummy) and the Hybrid III were evaluated in pendulum impacts to the back and compared to data from previous cadaver tests. The test setup impacting seated cadavers was reproduced with a pendulum impacting seated dummies at the level of T6 (6th thoracic vertebra). The pendulum mass was 23 kg and the impact velocity 4.6 m/s. The results showed that the BioRID P3 was more biofidelic than the Hybrid III in terms of the peak responses and the temporal window of the head and head relative to T1 horizontal, vertical, and angular displacement. This study is an evaluation of both the BioRID P3 and the Hybrid III against a recently available set of human subject data. The study meets the need for validation of the BioRID P3 at a higher impact severity than has been previously accomplished.

Key concepts: Pendulum, Hybrid III, Cadaver, Head (geology), Displacement (psychology), Orthodontics, Engineering, Structural engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of the BioRID P3 and the Hybrid III in pendulum impacts to the back--a comparison to human subject test data. — Research Paper | ScholarLens