2012Research Repository (Delft University of Technology)Open access

Fire safety engineering of high rise timber buildings

G. Longhi

Open full text 0 citations

Abstract

During this MSc thesis it has been carried out an extensive literature review on fire safety engineering, on timber behaviour on fire and on fire safety regulations in different countries. A preliminary design for a high rise cross laminated timber building (CLT) has been carried out in order to obtain a minimum thickness of the structural elements needed for the load bearing structure. This thickness has been verified according to prescriptive fire regulations. Furthermore, fire safety analyses have been performed to evaluate a more realistic fire behaviour of exposed timber structures. The finite element program SAFIR and the fire model OZone have been used in the advance calculations. Finally, it is shown that timber buildings should be designed according to advance fire safety approach and suggestions are given for developing a timber fire model.

Open-access reader

About this research paper

What this paper is about

During this MSc thesis it has been carried out an extensive literature review on fire safety engineering, on timber behaviour on fire and on fire safety regulations in different countries. A preliminary design for a high rise cross laminated timber building (CLT) has been carried out in order to obtain a minimum thickness of the structural elements needed for the load bearing structure. This thickness has been verified according to prescriptive fire regulations. Furthermore, fire safety analyses have been performed to evaluate a more realistic fire behaviour of exposed timber structures. The finite element program SAFIR and the fire model OZone have been used in the advance calculations. Finally, it is shown that timber buildings should be designed according to advance fire safety approach and suggestions are given for developing a timber fire model.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During this MSc thesis it has been carried out an extensive literature review on fire safety engineering, on timber behaviour on fire and on fire safety regulations in different countries. A preliminary design for a high rise cross laminated timber building (CLT) has been carried out in order to obtain a minimum thickness of the structural elements needed for the load bearing structure. This thickness has been verified according to prescriptive fire regulations. Furthermore, fire safety analyses have been performed to evaluate a more realistic fire behaviour of exposed timber structures. The finite element program SAFIR and the fire model OZone have been used in the advance calculations. Finally, it is shown that timber buildings should be designed according to advance fire safety approach and suggestions are given for developing a timber fire model.

Key concepts: Fire safety, Cross laminated timber, Engineering, Fire protection engineering, Load bearing, Fire protection, Architectural engineering, Civil engineering

Related papers