Ruffini Mechanoreceptors in Isolated Joint Capsule: Responses Correlated with Strain Energy Density
Peter Grigg, Allen H. Hoffman
Abstract
Peter Grigg, Allen H. Hoffman
Abstract
Mechanoreceptive afferents innervating the posterior capsule of the cat knee joint were recorded in a preparation of isolated capsule. The purpose of the experiments was to identify mechanical states in the capsule that were associated with afferent discharge. The capsule was excised from the knee with its bone attachments intact, so that the geometry of the capsule could be reproduced in vitro. The capsule was deformed, and measurements were made of stresses and strains in the plane of the capsule. Afferent discharge was correlated with each of the components of plane stress, plane strain, and strain energy density (SED). SED, the stored elastic energy at the receptor location, was the only mechanical variable that was consistently positively correlated with afferent discharge. A model of the Ruffini-type receptor is presented that accounts for the sensitivity to SED.
OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Mechanoreceptive afferents innervating the posterior capsule of the cat knee joint were recorded in a preparation of isolated capsule. The purpose of the experiments was to identify mechanical states in the capsule that were associated with afferent discharge. The capsule was excised from the knee with its bone attachments intact, so that the geometry of the capsule could be reproduced in vitro. The capsule was deformed, and measurements were made of stresses and strains in the plane of the capsule. Afferent discharge was correlated with each of the components of plane stress, plane strain, and strain energy density (SED). SED, the stored elastic energy at the receptor location, was the only mechanical variable that was consistently positively correlated with afferent discharge. A model of the Ruffini-type receptor is presented that accounts for the sensitivity to SED.
Key concepts: Capsule, Joint capsule, Afferent, Strain (injury), Strain energy density function, Materials science, Anatomy, Articular capsule of the knee joint