1974NASA Technical Reports Server (NASA)Requires access

Effect of rotor-to-stator spacing on acoustic performance of a full-scale fan (QF-5) for turbofan engines

J. R. Balombin, E. G. Stakolich

Open publisher page 7 citations

Abstract

A study was made of the effect of increasing the fan rotor-to-stator spacing on the noise level of a full-scale, single-stage, 1.6-pressure-ratio fan. Noise data were obtained with axial spacing of 1.14, 1.65, and 2.27 rotor chord lengths. Over this spacing range, data indicate a reduction of 1.5 PNdb. Apparently, rotor-alone noise at the frequency at which the rotor-stator interaction noise was cut off limited the noise reduction for the QF-5 fan. It seems, however, that the reduction in sound power level with increases in spacing is potentially about 6 db over the range of spacing tested.

About this research paper

What this paper is about

A study was made of the effect of increasing the fan rotor-to-stator spacing on the noise level of a full-scale, single-stage, 1.6-pressure-ratio fan. Noise data were obtained with axial spacing of 1.14, 1.65, and 2.27 rotor chord lengths. Over this spacing range, data indicate a reduction of 1.5 PNdb. Apparently, rotor-alone noise at the frequency at which the rotor-stator interaction noise was cut off limited the noise reduction for the QF-5 fan. It seems, however, that the reduction in sound power level with increases in spacing is potentially about 6 db over the range of spacing tested.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A study was made of the effect of increasing the fan rotor-to-stator spacing on the noise level of a full-scale, single-stage, 1.6-pressure-ratio fan. Noise data were obtained with axial spacing of 1.14, 1.65, and 2.27 rotor chord lengths. Over this spacing range, data indicate a reduction of 1.5 PNdb. Apparently, rotor-alone noise at the frequency at which the rotor-stator interaction noise was cut off limited the noise reduction for the QF-5 fan. It seems, however, that the reduction in sound power level with increases in spacing is potentially about 6 db over the range of spacing tested.

Key concepts: Turbofan, Stator, Rotor (electric), Acoustics, Noise (video), Sound power, Chord (peer-to-peer), Noise reduction

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of rotor-to-stator spacing on acoustic performance of a full-scale fan (QF-5) for turbofan engines — Research Paper | ScholarLens